9
-
91
(3) Process CPU
*1: The time-limit value of the internal timer is set by default.
In the PLC system tab of the PLC parameter dialog box, the value can be changed within the range of 0.5ms to 1000ms in increments of
0.5ms.
*2: This is applicable to the module whose serial number (first five digits) is "07032" or later.
*3: In the case of a multiple CPU system, this is applicable only to CPU No.1 when serial numbers (first five digits) of all CPU modules are
"07032" or later.
*4: After processing for "I32 (all of stop errors)" is completed, the Process CPU stops.
*5: Execution of I32 to I48 will be disabled (DI) if the system is powered on or when the Process CPU is reset.
To use any of I32 to I48, enable the interrupt with the IMASK instruction.
For the IMASK instruction, refer to the following.
MELSEC-Q/L Programming Manual (Common Instruction)
*6: To use the intelligent function module interrupt, the intelligent function module setting (interrupt pointer setting) is required in the PLC
system tab of the PLC parameter dialog box. (For interrupt from an intelligent function module, refer to Section 6.23.)
*7: I50 has the highest priority (priority 2), and I255 has the lowest priority (priority 207).
Table9.17 List of interrupt pointer numbers and interrupt factors (Process CPU)
I No.
Interrupt factor
Priority
I No.
Interrupt factor
Priority
I0
Interrupt by interrupt
module (QI60)
1st point
208
I32
*4
Interrupt by an
error
*4 *5
All of stop errors
1
I1
2nd point
209
I33
SINGLE PS. DOWN
*2 *3
I2
3rd point
210
I34
UNIT VERIFY ERR.,
FUSE BREAK OFF,
SP. UNIT ERROR,
MULTI CPU ERROR
I3
4th point
211
I4
5th point
212
I5
6th point
213
I35
OPERATION ERROR,
SFCP OPE. ERROR,
SFCP EXE. ERROR,
EX.POWER OFF
I6
7th point
214
I7
8th point
215
I8
9th point
216
I9
10th point
217
I36
ICM. OPE ERROR,
FILE OPE. ERROR
I10
11th point
218
I11
12th point
219
I37
Empty
I12
13th point
220
I38
PRG. TIME OVER
I13
14th point
221
I39
CHK instruction
execution, annunciator
detection
I14
15th point
222
I15
16th point
223
I40 to
49
Empty
I16 to
I27
Empty
I50 to
255
Intelligent
function module
interrupt
*6 *7
Specify the intelligent
function module or
interrupt module (QI60)
with a parameter.
2 to 207
I28
Interrupt by
internal timer
*1
100ms
227
I29
40ms
226
I30
20ms
225
I31
10ms
224