6
-
46
When local devices are set to be monitored and the program "B" is displayed for monitoring, the local device(s)
used in the program "B" can be monitored.
Figure 6.34 Local device monitor example
GX Developer
Local devices are set to be
monitored and the
program "B" is monitored.
The local device data of the
program B is displayed.
(Example)
If D0 to D99 are set as a local device,
D0=4 is displayed when X10 is on and
D99=8 is displayed when X11 is on.
X0
X1
X10
X11
X20
X21
MOVP K2 DO
MOVP K3 D99
MOVP K4 DO
MOVP K8 D99
MOVP K3 DO
MOVP K6 D99
Program: A
Program: B
Program: C
CPU module
Program execution (A B C)