9
-
104
CHAPTER9 DEVICES
9
9.13 C
onve
nient
Usag
e of Devices
9.13.2
Local device
●
If the size setting of the local device in the standard RAM is changed with a sampling trace file stored in the standard
RAM, the sampling trace file is cleared.
To save the trace results in your personal computer, perform the following operations.
1) Click the
button on the Sampling trace dialog box to read the trace result into the
personal computer. (
2) Click the
button to display the trace result.
3) Click the
button to store the trace results in CSV format.
●
All of the devices that have not been set as local devices are global devices.
(4) Setting of whether to use a local device (for each program)
Use of the local device can be set for each program, and this function can reduce the scan time.
Also, since the area for saving and restoring data is not required for the programs not using a local device, the
local device file size can be reduced.
Figure 9.104 Save area configuration of a local device file
Trace result PLC read
Trace result
Create CSV file
Program execution
Local device file (.QDL)
Program A
Program B
Program C
For program A
For program B
For program C
Save/Restore
Save/Restore
Save/Restore
Scan time decreases because saving
/restoring process is not performed.