![Mitsubishi Electric SW1DNN-WS0ADR-B Скачать руководство пользователя страница 187](http://html.mh-extra.com/html/mitsubishi-electric/sw1dnn-ws0adr-b/sw1dnn-ws0adr-b_operating-manual_1811861187.webp)
Chapter 9
184
Logic programming – Function blocks
Waiting time
The
Waiting time
parameter defines the time between the first rising edge of the
Inch
forward
or
Inch backward
input and the start of the
Release time
.
Release time
After the
Waiting time
has expired, the
Release time
begins. During the
Release
time
a rising edge on one of the
Inch forward
/
Inch backward
inputs will start the
machine (depending on the setting of the
Direction switching
parameter).
Signal time
The
Signal time
starts at the same time as the
Waiting time
. During the
Signal time
the
Warning
output becomes High, indicating that a start sequence has been initiated.
Impulse time
The
Impulse time
starts at the same time as the
Release time
. During the impulse
time the
Warning
output becomes High again, indicating that the inch mode can now
be started. If during the
Impulse time
the inch mode is started this has no effect on
the
Impulse time
, i.e. the
Warning
output will remain High until the configured
Impulse time
has expired.
The second warning signal is not mandatory and may be disabled by setting the
impulse time to 0 s.
Control input
A start sequence can only be initiated if the
Control
input is Low. If the
Control
input
changes to High during a start sequence, the start sequence is aborted and another
start sequence can only be initiated after the
Control
input has changed to Low again.
Lock input
A start sequence can only be initiated if the
Lock
input is High. If the
Lock
input
changes to Low during a start sequence, the start sequence is aborted and another
start sequence can only be initiated after the
Lock
input has changed to High again.
This input can be used for safety stops.
If inch mode is active, a falling edge at the
Lock
input will stop inch mode and set the
function block back into Waiting for start mode.
Stop input
A start sequence can only be initiated if the
Stop
input is High. If the
Stop
input
changes to Low during a start sequence, the start sequence is aborted and another
start sequence can only be initiated after the
Stop
input has changed to High again.
This input can be used for safety stops.
If inch mode is active, a falling edge at the
Stop
input will stop inch mode and set the
function block back into Waiting for start mode.
Inch forward/Inch backward
If a rising edge (transition from Low to High) is detected on the
Inch forward
or on the
Inch backward
input while the other input remains Low, the start sequence will begin.
A rising edge on both inputs or a rising edge on one of these inputs while the other
input is High is considered an invalid input state. If this occurs during a start sequence
(waiting time or release time running), these rising edges have no effect. If this occurs
during inch mode, the inch mode will be stopped and the release time starts again.
Note
Note
Содержание SW1DNN-WS0ADR-B
Страница 2: ......
Страница 287: ...Chapter 15 284 Annex 15 Annex 15 1 Example application reports 15 1 1 Example application Newspaper palletizer ...
Страница 288: ...Chapter 15 285 Annex ...
Страница 289: ...Chapter 15 286 Annex ...
Страница 290: ...Chapter 15 287 Annex ...
Страница 291: ...Chapter 15 288 Annex ...
Страница 292: ...Chapter 15 289 Annex ...
Страница 293: ...Chapter 15 290 Annex ...
Страница 294: ...Chapter 15 291 Annex ...
Страница 295: ...Chapter 15 292 Annex ...
Страница 296: ...Chapter 15 293 Annex ...
Страница 297: ...Chapter 15 294 Annex ...
Страница 298: ...Chapter 15 295 Annex 15 1 2 Example application Wood scanner ...
Страница 299: ...Chapter 15 296 Annex ...
Страница 300: ...Chapter 15 297 Annex ...
Страница 301: ...Chapter 15 298 Annex ...
Страница 302: ...Chapter 15 299 Annex ...
Страница 303: ...Chapter 15 300 Annex ...
Страница 304: ...Chapter 15 301 Annex ...
Страница 305: ...Chapter 15 302 Annex ...
Страница 306: ...Chapter 15 303 Annex ...
Страница 307: ...Chapter 15 304 Annex 15 1 3 Example application Ramp down detection ...
Страница 308: ...Chapter 15 305 Annex ...
Страница 309: ...Chapter 15 306 Annex ...
Страница 310: ...Chapter 15 307 Annex ...
Страница 311: ...Chapter 15 308 Annex ...
Страница 312: ...Chapter 15 309 Annex ...
Страница 313: ...Chapter 15 310 Annex ...
Страница 314: ...Chapter 15 311 Annex ...
Страница 316: ...Chapter 15 313 Annex 15 3 Precautions 1 Edit a CSV file exported from Setting and Monitoring tool in a text editor ...
Страница 321: ......