2 - 36
2 SYSTEM CONFIGURATION
(2) Motion SFC performance specifications
Item Specifications
Code total
(Motion SFC chart + Operation control
+ Transition)
543k bytes
Motion SFC program
capacity
Text total
(Operation c Transition)
484k bytes
Number of Motion SFC programs
256 (No.0 to 255)
Motion SFC chart size/program
Up to 64k bytes (Included Motion SFC chart comments)
Number of Motion SFC steps/program
Up to 4094 steps
Number of selective branches/branch
255
Number of parallel branches/branch
255
Motion SFC program
Parallel branch nesting
Up to 4 levels
Number of operation control programs
4096 with F(Once execution type) and FS(Scan execution type)
combined. (F/FS0 to F/FS4095)
Number of transition programs
4096(G0 to G4095)
Code size/program
Up to approx. 64k bytes (32766 steps)
Number of blocks(line)/program
Up to 8192 blocks (in the case of 4 steps(min)/blocks)
Number of characters/block
Up to 128 (comment included)
Number of operand/block
Up to 64 (operand: constants, word device, bit devices)
( ) nesting/block
Up to 32 levels
Operation control program
Calculation expression/bit conditional expression
Operation control program
(F/FS)
/
Transition program
(G)
Descriptive
expression Transition program
Calculation expression/bit conditional expression/
comparison conditional expression
Number of multi execute programs
Up to 256
Number of multi active steps
Up to 256 steps/all programs
Normal task
Execute in main cycle of Motion controller
Execute specification
Executed
task
Event task
(Execution
can be
masked.)
Fixed cycle
Execute in fixed cycle
(0.44ms, 0.88ms, 1.77ms, 3.55ms, 7.11ms, 14.2ms)
I/O (X,Y) points
8192 points
I/O (PX, PY) points
Internal I/F (Input 4 points, Output 2 points)
internal relays (M)
12288 points
Link relays (B)
8192 points
Annunciators relays (F)
2048 points
Special relays (SM)
2256 points
Data registers (D)
8192 points
Link registers (W)
8192 points
Special registers (SD)
2256 points
Motion registers (#)
12288 points
Coasting timers (FT)
1 point (888µs)
Number of devices
(Devices in the Motion
controller only)
(Positioning dedicated
devices are included)
Multiple CPU area device
None
Содержание MR-MQ100
Страница 1: ......
Страница 19: ...A 18 MEMO ...
Страница 73: ...3 12 3 DESIGN MEMO ...
Страница 97: ...5 8 5 TRIAL OPERATION AND ADJUSTMENT MEMO ...
Страница 159: ...7 36 7 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 167: ...8 8 8 PARAMETERS FOR POSITIONING CONTROL MEMO ...
Страница 189: ...9 22 9 SERVO PROGRAMS FOR POSITIONING CONTROL MEMO ...
Страница 205: ...10 16 10 MOTION SFC PROGRAMS MEMO ...
Страница 245: ...14 4 14 ERROR CODE MEMO ...
Страница 253: ...15 8 15 EMC DIRECTIVES MEMO ...
Страница 267: ...App 14 APPENDICES MEMO ...
Страница 270: ......
Страница 271: ......