2 - 13
2 SYSTEM CONFIGURATION
(4) Operation mode
(a) Rotary switch setting and operation mode
Rotary switch setting
(Note)
SW1 SW2
Operation mode
A Any
setting
(Except
C) Installation mode
0
0
Mode operated by RAM
0
6
Mode operated by ROM
0
8
Ethernet IP address display mode
Any setting
C
SRAM clear
(Note)
(Note) : The programs, parameters, absolute position data, and latch data built-in Motion
controller are cleared.
(b) Operation mode overview
Operation mode
7-segment LED
Operation overview
Mode operated by
RAM
• " . " remains flashing in the first digit of 7-segment LED.
• Operates based on the user program and parameters stored in the SRAM of
the Motion controller.
Mode operated by
ROM
• " . " remains flashing in the first digit and steady " . " display in the second
digit of 7-segment LED.
• Operation starts after the user programs and parameters stored in the Motion
controller’s FLASH ROM are read to the SRAM built-in Motion controller at
power supply on or reset of the Motion controller.
If the ROM writing is not executed, even if the user programs and
parameters are changed using the MT Developer2 during mode operated by
ROM, operation starts with the contents of the FLASH ROM at next power
supply on or reset.
Also, If the ROM writing is not executed, even if the auto tuning data are
reflected on the servo parameter of the Motion controller by operation in the
auto-tuning setting, operation starts with the contents of the FLASH ROM at
next power on or reset.
Ethernet IP address
display mode
-
• Refer to next page "(c) Ethernet IP address display mode overview".
• Digital oscilloscope function cannot be used.
SRAM clear
• " . " remains flashing in the first digit and steady.
• When rotary switch 2 is set to "C", and a power ON is done, the SRAM area
is cleared.
• The programs, parameters, absolute position data, and latch data in the
Motion controller are cleared.
Installation mode
• Steady "INS" display at the 7-segment LED.
• Operating system software can be installed.
• STOP status is maintained regardless of the RUN/STOP/RESET switch
position on the front side of Motion controller.
• Digital oscilloscope function cannot be used.
Содержание MR-MQ100
Страница 1: ......
Страница 19: ...A 18 MEMO ...
Страница 73: ...3 12 3 DESIGN MEMO ...
Страница 97: ...5 8 5 TRIAL OPERATION AND ADJUSTMENT MEMO ...
Страница 159: ...7 36 7 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 167: ...8 8 8 PARAMETERS FOR POSITIONING CONTROL MEMO ...
Страница 189: ...9 22 9 SERVO PROGRAMS FOR POSITIONING CONTROL MEMO ...
Страница 205: ...10 16 10 MOTION SFC PROGRAMS MEMO ...
Страница 245: ...14 4 14 ERROR CODE MEMO ...
Страница 253: ...15 8 15 EMC DIRECTIVES MEMO ...
Страница 267: ...App 14 APPENDICES MEMO ...
Страница 270: ......
Страница 271: ......