7 - 16
7 POSITIONING DEDICATED SIGNALS
7.3.3 Control change register list
Refer to "Q173DCPU/Q172DCPU Motion controller (SV13/SV22) Programming
Manual (REAL MODE)" for details.
Axis
No.
Device No.
Signal name
1 D640,
D641
2 D642,
D643
3 D644,
D645
Signal name
Real
Virtual
Fetch cycle
Unit
Signal
direction
4 D646,
D647
0
5 D648,
D649
1
JOG speed setting
At start
Command
unit
Command
device
6 D650,
D651
: Valid, : Invalid
7 D652,
D653
8 D654,
D655
POINT
(1) Only axis 1 can be set as a real mode. Axes 1 to 8 can be set as a virtual servo
motor axis. (Up to 3 axes can be used)