2 - 21
2 SYSTEM CONFIGURATION
(c) Interface between Manual pulse generator (Voltage-output/
Open-collector type)/ Incremental synchronous encoder
A
Manual pulse
generator/
Incremental
synchronous
encoder
Input or
Output
Signal name
Pin No.
Wiring example Internal circuit
Specification
Description
5V
Input
20
Manual
pulse
generator,
phase A
21
49
Power
supply
5V
SG
45
46
47
48
50
SG
No connect
Rated input voltage
5.5VDC or less
HIGH level
3 to 5.25VDC/
2mA or less
1VDC or less/
5mA or more
For connection
manual pulse
generator
Phases A, B
Pulse width
(1) Address increases
if Phase A leads
Phase B.
Phase difference
B
Power supply
5VDC
Manual
pulse
generator,
phase B
HA
HB
LOW level
(2) Address decreases
if Phase B leads
Phase A.
Select type
signal
SEL
(Note)
Phase A
2.5 s or
Phase B
more
(Duty ratio: 50% 25%)
5 s or more
2.5 s
or more
2.5 s
or more
Leading edge, Trailing
edge time 1.2 s or less.
(Note) : The 5VDC power supply from the MR-MQ100 must not be used if a separate power supply is
applied to the Manual pulse generator/ incremental synchronous encoder.
If a separate power supply is used, be sure it is 5V voltage. Anything else may cause a failure.
Содержание MR-MQ100
Страница 1: ......
Страница 19: ...A 18 MEMO ...
Страница 73: ...3 12 3 DESIGN MEMO ...
Страница 97: ...5 8 5 TRIAL OPERATION AND ADJUSTMENT MEMO ...
Страница 159: ...7 36 7 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 167: ...8 8 8 PARAMETERS FOR POSITIONING CONTROL MEMO ...
Страница 189: ...9 22 9 SERVO PROGRAMS FOR POSITIONING CONTROL MEMO ...
Страница 205: ...10 16 10 MOTION SFC PROGRAMS MEMO ...
Страница 245: ...14 4 14 ERROR CODE MEMO ...
Страница 253: ...15 8 15 EMC DIRECTIVES MEMO ...
Страница 267: ...App 14 APPENDICES MEMO ...
Страница 270: ......
Страница 271: ......