8 - 4
8 PARAMETERS FOR POSITIONING CONTROL
8.3 JOG Operation Data
(1) The settings for JOG operation is executed.
(2) Individual start or simultaneous start can be used in JOG operation.
(3) JOG operation can be executed using the Motion SFC program or test mode of
MT Developer2.
(Refer to the help of MT Developer2 for JOG operation method in the test mode of
MT Developer2.)
(4) Refer to "Q173DCPU/Q172DCPU Motion controller (SV13/SV22) Programming
Manual (REAL MODE)" for details.
Table 8.3 JOG operation data list
Setting range
mm inch degree PLS
No. Item
Setting
range
Units
Setting
range
Units
Setting
range
Units Setting range
Units
Initial
value
Units
Remarks
1
JOG
speed limit
value
0.01 to
6000000.00
mm
/min
0.001 to
600000.000
inch
/min
0.001 to
2147483.647
(Note-1)
degree/
min
1 to
2147483647
PLS
/s
20000 PLS/s
• Sets the maximum speed at the JOG
operation.
• If JOG speed setting exceeds the JOG
speed limit value, it is controlled with JOG
speed limit value.
2
Parameter
block
setting
1 to 64
1
• Sets the parameter block No. to be used at
the JOG operation.
(Note-1): When the "speed control 10 multiplier speed setting for degree axis" is set to "valid", the setting range is 0.01 to 21474836.47[degree/min].
Содержание MR-MQ100
Страница 1: ......
Страница 19: ...A 18 MEMO ...
Страница 73: ...3 12 3 DESIGN MEMO ...
Страница 97: ...5 8 5 TRIAL OPERATION AND ADJUSTMENT MEMO ...
Страница 159: ...7 36 7 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 167: ...8 8 8 PARAMETERS FOR POSITIONING CONTROL MEMO ...
Страница 189: ...9 22 9 SERVO PROGRAMS FOR POSITIONING CONTROL MEMO ...
Страница 205: ...10 16 10 MOTION SFC PROGRAMS MEMO ...
Страница 245: ...14 4 14 ERROR CODE MEMO ...
Страница 253: ...15 8 15 EMC DIRECTIVES MEMO ...
Страница 267: ...App 14 APPENDICES MEMO ...
Страница 270: ......
Страница 271: ......