App. - 5
APPENDIX
App. 4.2 Configuration including auxiliary equipment (1.9 Configuration including auxiliary equipment)
P
C
MR Configurator
CN5
CN3
CN1A
CN1B
CN2
CN2L
Junction
terminal
block
Servo system
controller or Front axis
servo amplifier CN1B
Rear servo amplifier
CN1A or Cap
No-fuse breaker
(NFB) or fuse
Magnetic
contactor
(MC)
(Note 1)
Power factor
improving DC
reactor
(FR-BEL)
Regenerative option
Servo amplifier
(Note 2)
Load side encoder
R S T
Personal
computer
Line noise
filter
(FR-BSF01)
Servo motor
L
1
L
3
L
2
U
P
1
P
2
V
W
(Note 3)
Power supply
L
21
L
11
(Note 1)
Note 1. The AC reactor can be also used. In this case, the DC reactor cannot be used. When not using DC reactor, short P
1
and P
2
.
2. For the configuration of the ABZ-phase pulse train interface or serial communication specification linear encoder/rotary encoder,
refer to section 1.10.
3. Refer to section 1.3 for the power supply specification.