5. PARAMETERS
5.5 Extension control parameters (No.PE
)
POINT
Parameter whose symbol is preceded by * is made valid with the following
conditions.
* : Set the parameter value, switch power off once after setting, and then switch
it on again, or perform the controller reset.
**: Set the parameter value, switch power off once, and then switch it on again.
5.5.1 Parameter list
No. Symbol
Name
Initial
value
Unit
PE01 **FCT1 Fully closed loop selection 1
0000h
PE02
For manufacturer setting
0102h
PE03 *FCT2 Fully closed loop selection 2
0003h
PE04 **FBN Fully closed loop feedback pulse electronic gear numerator 1
1
PE05 **FBD Fully closed loop feedback pulse electronic gear denominator 1
1
PE06
BC1
Fully closed loop control speed deviation error detection level
400
r/min
PE07
BC2
Fully closed loop control postion deviation error detection level
100
kpulse
PE08
DUF
Fully closed loop dual feedback filter
10
rad/s
PE09
For manufacturer setting
0000h
PE10
FCT3
Fully closed loop selection 3
0000h
PE11
For manufacturer setting
0
PE12
40
PE13
FFFEh
PE14
0111h
PE15
20
PE16
0000h
PE17
0000h
PE18
0000h
PE19
0000h
PE20
0000h
PE21
0000h
PE22
0000h
PE23
0000h
PE24
0000h
PE25
0000h
PE26
0000h
PE27
0000h
PE28
0000h
PE29
0000h
PE30
0000h
PE31
0000h
PE32
0000h
PE33
0000h
PE34 **FBN2 Fully closed loop feedback pulse electronic gear numerator 2
1
PE35 **FBD2 Fully closed loop feedback pulse electronic gear denominator 2
1
PE36
For manufacturer setting
0.0
PE37
0.00
PE38
0.00
PE39
0000h
PE40
0000h