WWW.NNC.IR
15 - 39
15. ABSOLUTE POSITION DETECTION SYSTEM
(2) Sequence program example
(a) Conditions
1) Operation pattern
ABS data transfer is made as soon as the servo-on switch is turned on. After that, positioning
operation is performed as shown below.
300000
0
address
3)
1)
2)
Home position
300000
After the completion of ABS data transmission, JOG operation is possible using the JOG or
JOG switch, and dog type home position return is possible using the home position return
switch.
2) Buffer memory assignment
For BFM#26 and later, refer to the FX
2(N)
-1PG User's Manual.
BMF No.
Upper 16
bits
Lower 16
bits
Name and symbol
Set value
Remark
-
#0
Pulse rate
A
2000
#2
#1
Feed rate
B
1000
-
#3
Parameter
H0000
Command unit: Pulses
#5
#4
Max. speed
Vmax
100000PPS
-
#6
Bias speed
Vbia
0PPS
#8
#7
JOG operation
Vjog
10000PPS
#10
#9
Home position return speed (high speed)
V
RT
50000PPS
-
#11
Home position return speed (creep)
V
CL
1000PPS
-
#12
Home position return zero-point signal count N
2 pulses
Initial value: 10
#14
#13
Home position address
HP
0
-
#15
Acceleration/deceleration time
Ta
200ms
Initial value: 100
-
#16
Not usable
#18
#17
Target address (I)
P(I)
0
#20
#19
Operation speed (I)
V(I)
100000
Initial value: 10
#22
#21
Target address (II)
P(II)
0
#24
#23
Operation speed (II)
V(II)
10
-
#25
Operation command
H0000
3) Instructions
When the servo-on switch and the COM of the power supply are shorted, the ABS data is
transmitted when the servo amplifier power is turned ON, or at the leading edge of the RUN
signal after a PC reset operation (PC-RESET). The ABS data is also transmitted when an alarm
is reset, or when the emergency stop state is reset.
If checksum discrepancy is detected in the transmitted data, the ABS data transmission is
retried up to three times. If the checksum discrepancy is still detected after retrying, the ABS
checksum error is generated (Y12 ON).
The following time periods are measured and if the ON/OFF state does not change within the
specified time, the ABS communication error is generated (Y11 ON).
ON period of ABS transfer mode (Y1)
ON period of ABS request (Y2)
OFF period of ready to send the ABS data (X2).
Содержание MR-J2S-*A
Страница 13: ...WWW NNC IR A 12 MEMO ...
Страница 117: ...WWW NNC IR 3 70 3 SIGNALS AND WIRING MEMO ...
Страница 185: ...WWW NNC IR 7 12 7 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 195: ...WWW NNC IR 8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 197: ...WWW NNC IR 9 2 9 INSPECTION MEMO ...
Страница 221: ...WWW NNC IR 11 10 11 OUTLINE DIMENSION DRAWINGS MEMO ...
Страница 293: ...WWW NNC IR 13 64 13 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...
Страница 321: ...WWW NNC IR 14 28 14 COMMUNICATION FUNCTIONS MEMO ...
Страница 389: ...WWW NNC IR 15 68 15 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...