13 - 18
13. OPTIONS AND AUXILIARY EQUIPMENT
(2) Connection example
(Note 5)
Power supply
NFB
MC
Servo amplifier
L
11
L
21
L
1
L
2
L
3
SK
ON
MC
B C
RDY
SE
Alarm
output
RDY
output
A
B
C
Operation ready
MC
OFF
EMG
RA2
FR-RC
Ready
(Note 3) Power factor improving reactor
FR-BAL
R/L
1
S/L
2
T/L
3
B
C
EMG
SON
SG
COM
ALM
VDD
RA2
R
RX
R
SX
S
TX
T
Phase detection
terminals
(Note 1)
Power regeneration
converter FR-RC
N
P
5m(16.4ft) or less
N/
P/
(Note 2)
C
P
1
(Note 4)
Note 1. When not using the phase detection terminals, fit the jumpers across RX-R, SX-S and TX-T. If the jumpers remain removed, the
FR-RC will not operate.
2. For the servo amplifiers of 5k and 7kW, always remove the wiring (across P-C) of the built-in regenerative resistor.
3. Refer to the power return converter FR-RC instruction manual (IB(NA)-66330) for the power factor improving reactor to be
used.
When using FR-RC with the servo amplifier of 11k to 22kW, do not use the power factor improving reactor (FR-BEL) together.
4. When using the servo amplifier of 11k to 22kW, make sure to connect P
1
and P. (Factory-wired.)
5. Refer to section 1.3 for the power supply specification.
Содержание MR-J2S-*A
Страница 13: ...WWW NNC IR A 12 MEMO ...
Страница 117: ...WWW NNC IR 3 70 3 SIGNALS AND WIRING MEMO ...
Страница 185: ...WWW NNC IR 7 12 7 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 195: ...WWW NNC IR 8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 197: ...WWW NNC IR 9 2 9 INSPECTION MEMO ...
Страница 221: ...WWW NNC IR 11 10 11 OUTLINE DIMENSION DRAWINGS MEMO ...
Страница 293: ...WWW NNC IR 13 64 13 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...
Страница 321: ...WWW NNC IR 14 28 14 COMMUNICATION FUNCTIONS MEMO ...
Страница 389: ...WWW NNC IR 15 68 15 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...