WWW.NNC.IR
13 - 3
13. OPTIONS AND AUXILIARY EQUIPMENT
b. Losses of servo motor and servo amplifier in regenerative mode
The following table lists the efficiencies and other data of the servo motor and servo amplifier in
the regenerative mode.
Servo amplifier
Inverse efficiency[%]
Capacitor charging[J]
MR-J2S-10A
55
9
MR-J2S-10A1
55
4
MR-J2S-20A
70
9
MR-J2S-20A1
70
4
MR-J2S-40A
85
11
MR-J2S-40A1
85
12
MR-J2S-60A
85
11
MR-J2S-70A
80
18
MR-J2S-100A
80
18
MR-J2S-200A
85
40
MR-J2S-350A
85
40
MR-J2S-500A
90
45
MR-J2S-700A
90
70
MR-J2S-11KA
90
120
MR-J2S-15KA
90
170
MR-J2S-22KA
90
250
Inverse efficiency ( )
:Efficiency including some efficiencies of the servo motor and servo
amplifier when rated (regenerative) torque is generated at rated speed.
Since the efficiency varies with the speed and generated torque, allow for
about 10%.
Capacitor charging (Ec) :Energy charged into the electrolytic capacitor in the servo amplifier.
Subtract the capacitor charging from the result of multiplying the sum total of regenerative energies
by the inverse efficiency to calculate the energy consumed by the regenerative option.
ER [J]
Es Ec
Calculate the power consumption of the regenerative option on the basis of single-cycle operation
period tf [s] to select the necessary regenerative option.
PR [W] ER/tf
(3) Connection of the regenerative option
Set parameter No.2 according to the option to be used.
The MR-RB65, 66 and 67 are regenerative options that have encased the GRZG400-2 , GRZG400-1
and GRZG400-0.8 , respectively. When using any of these regenerative options, make the same
parameter setting as when using the GRZG400-2 , GRZG400-1 or GRZG400-0.8 (supplied
regenerative resistors or regenerative option is used with 11kW or more servo amplifier).
Parameter No.0
Selection of regenerative
00: Regenerative option or regenerative option is not used with 7kW or
less servo amplifier
Supplied regenerative resistors or regenerative option is used with
11kW or more servo amplifier
01: FR-RC, FR-BU2, FR-CV
02: MR-RB032
03: MR-RB12
04: MR-RB32
05: MR-RB30
06: MR-RB50 (Cooling fan is required)
08: MR-RB31
09: MR-RB51 (Cooling fan is required)
0E: When regenerative resistors supplied to 11kW or more are cooled by
cooling fans to increase capability
Содержание MR-J2S-*A
Страница 13: ...WWW NNC IR A 12 MEMO ...
Страница 117: ...WWW NNC IR 3 70 3 SIGNALS AND WIRING MEMO ...
Страница 185: ...WWW NNC IR 7 12 7 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 195: ...WWW NNC IR 8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 197: ...WWW NNC IR 9 2 9 INSPECTION MEMO ...
Страница 221: ...WWW NNC IR 11 10 11 OUTLINE DIMENSION DRAWINGS MEMO ...
Страница 293: ...WWW NNC IR 13 64 13 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...
Страница 321: ...WWW NNC IR 14 28 14 COMMUNICATION FUNCTIONS MEMO ...