WWW.NNC.IR
5 - 30
5. PARAMETERS
5.2.2 Analog monitor
The servo status can be output to two channels in terms of voltage
.
The servo status can be monitored
using an ammeter.
(1) Setting
Change the following digits of parameter No.17.
Analog monitor (MO1) output selection
(Signal output to across MO1-LG)
Analog monitor (MO2) output selection
(Signal output to across MO2-LG)
Parameter No. 17
0
0
Parameters No.31 and 32 can be used to set the offset voltages to the analog output voltages. The
setting range is between 999 and 999mV.
Parameter No.
Description
Setting range [mV]
31
Used to set the offset voltage for the analog monitor 1 (MO1).
32
Used to set the offset voltage for the analog monitor 2 (MO2)
output.
999 to 999