WWW.NNC.IR
15 - 21
15. ABSOLUTE POSITION DETECTION SYSTEM
15.7.4 Use of servo motor with electromagnetic brake
The timing charts at power on/off and servo-on (SON) on/off are given below.
Preset " 1 " in parameter No. 1 to make the electromagnetic brake interlock (MBR) usable. When the
ABS transfer mode is ON, the electromagnetic brake interlock (MBR) is used as the ABS data bit 1.
Hence, make up an external sequence which will cause the electromagnetic brake torque to be generated
by the ABS mode (ABSM) and electromagnetic brake interlock (MBR).
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
80 [ms]
20 [ms]
Tb
80 [ms]
20 [ms]
Tb
Power
supply
Servo-on
(SON)
ABS transfer mode
(ABSM)
ABS request
(ABSR)
ABS transmission
data ready
(ABST)
Send (ABS) data
Base circuit
Ready
(RD)
Electromagnetic
brake interlock
(MBR)
Electromagnetic
brake torque
During transmission
of ABS
During transmission
of ABS
ABS data
ABS data
Содержание MR-J2S-*A
Страница 13: ...WWW NNC IR A 12 MEMO ...
Страница 117: ...WWW NNC IR 3 70 3 SIGNALS AND WIRING MEMO ...
Страница 185: ...WWW NNC IR 7 12 7 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 195: ...WWW NNC IR 8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 197: ...WWW NNC IR 9 2 9 INSPECTION MEMO ...
Страница 221: ...WWW NNC IR 11 10 11 OUTLINE DIMENSION DRAWINGS MEMO ...
Страница 293: ...WWW NNC IR 13 64 13 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...
Страница 321: ...WWW NNC IR 14 28 14 COMMUNICATION FUNCTIONS MEMO ...
Страница 389: ...WWW NNC IR 15 68 15 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...