WWW.NNC.IR
13 - 5
13. OPTIONS AND AUXILIARY EQUIPMENT
(b) MR-J2S-500A MR-J2S-700A
Always remove the wiring (across P-C) of the servo amplifier built-in regenerative resistor and fit
the regenerative option across P-C.
The G3 and G4 terminals act as a thermal sensor. G3-G4 are opened when the regenerative option
overheats abnormally.
Servo amplifier
Regenerative option
Always remove wiring (across P-C) of servo
amplifier built-in regenerative resistor.
P
C
G4
G3
(Note 2)
5m(16.4ft) or less
Cooling fan(Note 1)
C
P
Note 1. When using the MR-RB50 MR-RB51, forcibly cool it with a cooling fan (92 92, minimum air flow: 1.0m
3
).
2. Make up a sequence which will switch off the magnetic contactor (MC) when abnormal heating occurs.
G3-G4 contact specifications
Maximum voltage: 120V AC/DC
Maximum current: 0.5A/4.8VDC
Maximum capacity: 2.4VA
When using the regenerative resistor option, remove the servo amplifier's built-in regenerative
resistor terminals (across P-C), fit them back to back, and secure them to the frame with the
accessory screw as shown below.
Mounting method
Accessory screw
For MR-J2S-500A
For MR-J2S-700A
Accessory screw
Accessory screw
Содержание MR-J2S-*A
Страница 13: ...WWW NNC IR A 12 MEMO ...
Страница 117: ...WWW NNC IR 3 70 3 SIGNALS AND WIRING MEMO ...
Страница 185: ...WWW NNC IR 7 12 7 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 195: ...WWW NNC IR 8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 197: ...WWW NNC IR 9 2 9 INSPECTION MEMO ...
Страница 221: ...WWW NNC IR 11 10 11 OUTLINE DIMENSION DRAWINGS MEMO ...
Страница 293: ...WWW NNC IR 13 64 13 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...
Страница 321: ...WWW NNC IR 14 28 14 COMMUNICATION FUNCTIONS MEMO ...
Страница 389: ...WWW NNC IR 15 68 15 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...