6. MODBUS REGISTERS
6 - 36
6.4.2 Quick stop option code (605Ah)
Address Name
Data
type
Read/
write
No. of Points/
No. of Registers
Continuous read/
continuous write
605Ah
Quick stop option code (Quick stop option code)
2 bytes
Read/
write
1 Impossible
The operation method of deceleration to a stop can be specified. The following table shows the supported
methods and the operations.
Setting
value
Description
1
For manufacturer setting
2
In the profile mode (pp/pv) and homing mode (hm), the servo motor decelerates to a stop with Quick stop deceleration
(6085h) and the state shifts to the Switch On Disabled state. The new setting of Quick stop deceleration is reflected at all
times.
In the profile torque mode (tq), the state immediately shifts to the Switch On Disabled state and the servo motor stops with
the dynamic brake.