6. MODBUS REGISTERS
6 - 5
Address
Name and function
Data
type
Read/
write
Initial value
Range
Unit
Saved
to EEP-
ROM
Para-
meter
No. of
Points/
No. of
Registers
Continuous
read/
continuous
write
2B30 Command
position
(Command position)
The command position is returned.
4
bytes
Reading 80000000h
to
7FFFFFFFh
2
Possible
2B31 Command remaining distance (Command
remaining distance)
The command remaining distance is returned.
4
bytes
Read
80000000h
to
7FFFFFFFh
2
Possible
2B81 Cumulative feedback pulses at alarm
occurrence (Alarm Monitor 1 Cumulative
feedback pulses)
The cumulative feedback pulses at alarm
occurrence are returned.
4
bytes
Reading 80000000h
to
7FFFFFFFh
pulse 2
Possible
2B82 Servo motor speed at alarm occurrence (Alarm
Monitor 2 Servo motor speed)
The servo motor speed at alarm occurrence is
returned.
4
bytes
Reading 80000000h
to
7FFFFFFFh
r/min 2
Possible
2B83 Droop pulses at alarm occurrence (Alarm
Monitor 3 Droop pulses)
The droop pulses at alarm occurrence are
returned.
4
bytes
Reading 80000000h
to
7FFFFFFFh
pulse 2
Possible
2B84 Cumulative command pulses at alarm
occurrence (Alarm Monitor 4 Cumulative
command pulses)
The cumulative command pulses (encoder
unit) at alarm occurrence are returned.
4
bytes
Reading 80000000h
to
7FFFFFFFh
pulse 2
Possible
2B85 Command pulse frequency at alarm
occurrence (Alarm Monitor 5 Command pulse
frequency)
The command pulse frequency at alarm
occurrence is returned.
4
bytes
Reading 80000000h
to
7FFFFFFFh
kpulse/s
2 Possible
2B86 Analog speed command voltage at alarm
occurrence
(Alarm Monitor 6 Analog speed command
voltage)
The analog speed command voltage at alarm
occurrence is returned.
2
bytes
Reading 8000h
to
7FFFh
V 1
Possible
2B87 Analog torque limit voltage/
Analog torque command voltage at alarm
occurrence (Alarm Monitor 7 Analog torque
limit voltage/
Analog torque command voltage)
The analog torque limit voltage/analog torque
command voltage at alarm occurrence is
returned.
2
bytes
Reading 8000h
to
7FFFh
V 1
Possible
2B88 Regenerative load ratio at alarm occurrence
(Alarm Monitor 8 Regenerative load ratio)
The regenerative load ratio at alarm
occurrence is returned.
2
bytes
Reading 0000h
to
FFFFh
% 1
Possible
2B89 Effective load ratio at alarm occurrence (Alarm
Monitor 9 Effective load ratio)
The effective load ratio at alarm occurrence is
returned.
2
bytes
Reading 0000h
to
FFFFh
% 1
Possible
2B8A Peak load ratio at alarm occurrence (Alarm
Monitor 10 Peak load ratio)
The peak load ratio at alarm occurrence is
returned.
2
bytes
Reading 0000h
to
FFFFh
% 1
Possible
2B8B Instantaneous torque at alarm occurrence
(Alarm Monitor 11 Instantaneous torque)
The instantaneous torque at alarm occurrence
is returned.
2
bytes
Reading 8000h
to
7FFFh
% 1
Possible
2B8C Position within one-revolution at alarm
occurrence (Alarm Monitor 12 Within one-
revolution position)
The position within one-revolution at alarm
occurrence is returned.
4
bytes
Reading 80000000h
to
7FFFFFFFh
pulse 2
Possible
2B8D Multi-revolution counter at alarm occurrence
(Alarm Monitor 13 ABS counter)
The ABS counter at alarm occurrence is
returned.
4
bytes
Reading 80000000h
to
7FFFFFFFh
rev 2
Possible