6. MODBUS REGISTERS
6 - 7
Address
Name and function
Data
type
Read/
write
Initial value
Range
Unit
Saved
to EEP-
ROM
Para-
meter
No. of
Points/
No. of
Registers
Continuous
read/
continuous
write
2C11 External output pin status (External Output pin
display)
The number of entries in external output pin
status is returned.
1
bytes
Read 1 01h
(fixed)
3
Impossible
External output pin status 1 (External Output
pin display1)
The external input pin status is returned.
4
bytes
Reading 00000000h
to
FFFFFFFFh
2C12 Input device status (External Input signal
display)
The number of entries in input device status is
returned.
1
bytes
Reading 4 04h
(fixed)
9
Impossible
Input device status 1 (External Input signal
display1)
The input device status 1 is returned.
4
bytes
Reading 00000000h
to
FFFFFFFFh
Input device status 2 (External Input signal
display2)
The input device status 2 is returned.
4
bytes
Reading 00000000h
to
FFFFFFFFh
Input device status 3 (External Input signal
display3)
The input device status 3 is returned.
4
bytes
Reading 00000000h
to
FFFFFFFFh
Input device status 4 (External Input signal
display4)
The input device status 4 is returned.
4
bytes
Reading 00000000h
to
FFFFFFFFh
2C18 Power ON cumulative time (Power ON
cumulative time)
The cumulative time after power on of the servo
amplifier is returned.
4
bytes
Reading 0 00000000h
to
FFFFFFFFh
hour 2
Impossible
2C19 Number of inrush relay ON/OFF times
(Number of inrush relay on/off times)
The number of on/off times of the inrush relay
of the servo amplifier is returned.
4
bytes
Reading 0 00000000h
to
FFFFFFFFh
times 2
Impossible
Содержание MELSERVO-JE MR-JE-C
Страница 9: ...A 8 MEMO ...
Страница 83: ...MEMO ...