5. MANUFACTURER FUNCTIONS
5 - 2
5.2 One-touch tuning
Refer to "MR-JE-_C Servo Amplifier Instruction Manual" for one-touch tuning. Using One-touch tuning mode
(2D50h) allows one-touch tuning from the client (controller).
(1) Related resister
Address Read/write
Name
Data
type
Initial
value
Description
2D50h
Read/write
One-touch tuning mode
1 bytes
0
Setting a value of "1" to "3" starts one-
touch tuning. After one-touch tuning is
completed, the setting value automatically
changes to "0".
0: During one-touch tuning stop
1: Basic mode
2: High mode
3: Low mode
2D51h
Reading
One-touch tuning status
1 bytes
0
Regardless of whether one-touch tuning is
properly completed or not, the setting
value changes to 100% at the completion.
Unit: %
2D52h
Writing
One-touch tuning Stop
2 bytes
0
Writing "1EA5h" stops one-touch tuning.
Writing a value other than "1EA5h" sets
0609 0030h Value range of parameter
exceeded in SDO Abort Code.
2D53h
Writing
One-touch tuning Clear
2 bytes
0
The parameter changed in one-touch
tuning can be returned to the value before
the change.
0000h: Restores the initial value.
0001h: Restores the value before one-
touch tuning.
The setting value of the restored
parameter is stored to the EEP-ROM.
2D54h
Reading
One-touch tuning Error Code
2 bytes
0
The following shows the details of the one-
touch tuning error codes.
0000h: Finished normally
C000h: Tuning canceled
C001h: Overshoot exceeded
C002h: Servo-off during tuning
C003h: Control mode error
C004h: Time-out
C005h: Load to motor inertia ratio
misestimated
C00Fh: One-touch tuning disabled