![Mitsubishi Electric MELSERVO-J2S-S061 Скачать руководство пользователя страница 83](http://html.mh-extra.com/html/mitsubishi-electric/melservo-j2s-s061/melservo-j2s-s061_specifications-and-instruction-manual_239181083.webp)
82
(11) Dwell time write
Write the dwell time of the point table.
Transmit command [C][A], any of data No. [0][1] to [1][F] corresponding to the point table to be
written to, and the data. Refer to Section 8.11.2.
Command Data
No.
Data
[C][A]
[0][1] to
[1][F]
See below.
0
Hexadecimal data
Write mode
0: EEP-ROM, RAM write
1: RAM write
When the positioning address is changed frequently through
communication, set "1" to the write mode to change only the RAM data in
the servo amplifier.
If the EEP-ROM value is changed frequently, EEP-ROM fault will occur
due to the excess of the permissible EEP-ROM write times.
(12) Auxiliary function write
Write the auxiliary function of the point table.
Transmit command [C][B], any of data No. [0][1] to [1][F] corresponding to the point table to be
written to, and the data. Refer to Section 8.11.2.
Command Data
No.
Data
[C][B]
[0][1] to
[1][F]
See below.
0
Hexadecimal data
Write mode
0: EEP-ROM, RAM write
1: RAM write
When the positioning address is changed frequently through
communication, set "1" to the write mode to change only the RAM data in
the servo amplifier.
If the EEP-ROM value is changed frequently, EEP-ROM fault will occur
due to the excess of the permissible EEP-ROM write times.