(1) Item list
Class
No.
Symbol
Name and Function
Initial Value
Unit
Customer
Setting
0
*STY
Control mode, regenerative brake option selection
0010
1
*FTY
Feeding function selection
0000
2
*OP1
Function selection 1
0002
3 AUT
Auto
tuning
0105
4 *CMX
Electronic
gear
numerator
1
5 *CDV
Electronic
gear
denominator
1
6
INP
Movement completion output range
100
pulse
7
PG1
Position loop gain 1
36
rad/s
8 ZTY
Zeroing
type
0013
9 ZRF
Zeroing
speed
500
r/min
10 CRF
Creep
speed
10
r/min
11
ZST
Zero shift distance
0
Um
12
CRP
Rough match output range
0
10
STM
m
13 JOG
JOG
speed
100
r/min
14
*STC
S-Curve acceleration/deceleration time constant
0
Ms
15
*SNO
Station number setting
0
station
16
*BPS
Alarm history clear
0000
17
MOD
For manufacture setting
0100
18 *DMD
Status
display
selection
0000
B
asi
c p
ara
meters
19 *BLK
Parameter
block
0000