![Mitsubishi Electric MELSERVO-J2S-S061 Скачать руководство пользователя страница 72](http://html.mh-extra.com/html/mitsubishi-electric/melservo-j2s-s061/melservo-j2s-s061_specifications-and-instruction-manual_239181072.webp)
71
8.12.4 External I/O signal statuses
(1) Reading of input device statuses
Read the statuses of the input devices.
(a) Transmission
Transmit command [1][2] and data No. [0][0].
Command Data
No.
[1][2] [0][0]
(b) Reply
The slave station sends back the statuses of the input pins.
b31
b0
0:OFF
1:ON
b1
Command of each bit is transmitted to the master
station as hexadecimal data.
bit Signal
Name bit Signal
Name bit Signal
Name
0 Servo on (SON)
10
20 Point table selection 2 (DI1)
1 Forward rotation stroke limit (LSP)
11 Forward rotation start (ST1)
21 Point table selection 3 (DI2)
2 Reverse rotation stroke limit (LSN)
12 Reverse rotation start (ST2)
22 Point table selection 4 (DI3)
3 External torque limit selection (TL)
13
23
4 Internal torque limit selection (TL2)
14
24 Temporary stop/restart (STP)
5 Proportion control selection (PC)
15
25
6 Alarm reset (RES)
16 Emergency stop (EMG)
26
7
17 Automatic/manual selection (MDO)
27 Gain changing (CDP)
8
18 Proximity dog (DOG)
28
9
19 Point table selection 1 (DI0)
29 Point table selection 5 (DI4)
(2) External input pin status read
Read the ON/OFF statuses of the external output pins.
(a) Transmission
Transmit command [1][2] and data No. [4][0].
Command Data
No.
[1][2] [4][0]
(b) Reply
The ON/OFF statuses of the input pins are sent back.
b31
b0
0:OFF
1:ON
b1
Command of each bit is transmitted to the master
station as hexadecimal data.
bit External Input Pin
bit External Input Pin
0 CN1B-16
5 CN1A-8
1 CN1B-17
6 CN1B-7
2 CN1B-15
7 CN1B-8
3 CN1B-5
8 CN1B-9
4 CN1B-14
9 CN1A-19