![Mitsubishi Electric MELSERVO-J2S-S061 Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/mitsubishi-electric/melservo-j2s-s061/melservo-j2s-s061_specifications-and-instruction-manual_239181042.webp)
41
BCN-B11127-479*
Class No. Symbol
Name
and
function
Initial
value
Unit Setting
range
61
NH1 Machine resonance suppression filter 1
Used to selection the machine resonance suppression filter.
0000
.0000h
to
031Fh
62
NH2 Machine resonance suppression filter 2
Used to set the machine resonance suppression filter.
0000
0000h
to
031Fh
2
3
0
0
1
40
d
B
14
d
B
8
d
B
4
d
B
Notch frequency selection
00
01
02
03
04
05
06
07
Setting
value
Frequency
Invalid
4500
2250
1500
1125
900
750
642.9
08
09
0A
0B
0C
0D
0E
0F
562.5
500
450
409.1
375
346.2
321.4
300
Frequency
10
11
12
13
14
15
16
17
281.3
264.7
250
236.8
225
214.3
204.5
195.7
Frequency
18
19
1A
1B
1C
1D
1E
1F
187.5
180
173.1
166.7
160.1
155.2
150
145.2
Frequency
Notch depth selection
Setting
value
Depth
Gain
Deep
Shallow
to
Setting
value
Setting
value
Setting
value
0
Notch frequency
Same setting as in parameter No. 61
However, you need not set "00" if you have
set adaptive vibration suppression control to
be "valid" or "held".
Notch depth
Same setting as in parameter No. 61