![Mitsubishi Electric MELSERVO-J2S-S061 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/mitsubishi-electric/melservo-j2s-s061/melservo-j2s-s061_specifications-and-instruction-manual_239181026.webp)
25
BCN-B11127-479*
(3) Operation
By shorting ST1-SG, operation is performed under the conditions of the jog speed set in the parameter
and the acceleration and deceleration time constants in set point table No.1. For the rotation direction,
refer to (2) in this section. By shorting ST2-SG, the servo motor rotates in the reverse direction to ST1.
(4) Timing chart
Servo on (SON)
Ready (RD)
Trouble (ALM)
Automatic/manual mode
selection (MDO)
In position (INP)
Rough match (CPO)
100ms
Motor speed
Forward rotation start (ST1)
Reverse rotation start (ST2)
Forward rotation jog
Reverse rotation jog
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Forward
rotation
Reverse
rotation
ON
OFF
ON
OFF
0r/min