117
Table 6.3 Error Code List for AnUCPU (Continue)
Error
Massage
Error
Code
(D9008)
Detailed
Error
Code
(D9091)
CPU
States
Error and Cause
Corrective Action
141 Instructions
(including
NOP ) other than
LDX ,
LDIX ,
ANDX and
ANIX are included
in the
CHK instruction
circuit block.
142
Multiple
CHK
instructions are given.
143
The number of contact
points in the CHK
instruction circuit block
exceeds 150.
144 The
LEDA CHK
instructions are not
paired with the
LEDA CHKEND
instructions, or 2 or
more pairs of them are
given.
145
Format of the block
shown below, which is
provided before the
CHK instruction
circuit block, is not as
specified.
CJ P
P254
146
Device number of D1
in the
CHK D1 D2
instruction is different
from that of the contact
point before the
CJ P
instruction.
"CHK
FORMAT
ERR"
(Checked
at
STOP/PAU
SE
→
RUN.)
14
147
STOP
Index qualification is
used in the check
pattern circuit.
Check the program of
the
CHK instruction and
correct it referring to
contents of detailed
error codes.