PARAMETERS
67
4.1.2 List of Parameters Classified by Purposes of Use
Set the parameters according to the operating conditions. The following list indicates purposes of use and
parameters.
Parameter Numbers
Purpose of Use
Parameter numbers which must be set
Switch-over to optimum excitation control operation
Pr. 14, Pr. 60
Adjustment of acceleration/deceleration time and
pattern
Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 160
Selection of optimum output characteristic for load
characteristic
Pr. 3, Pr. 14, Pr. 19, Pr. 60
Limit of output frequency
Pr. 1, Pr. 2
Operation over 60Hz
Pr. 903, Pr. 905
Adjustment of frequency setting signal and output
Pr. 73, Pr. 74, Pr. 902 to Pr. 905
Adjustment of motor output torque
Pr. 0
Adjustment of brake operation
Pr. 10, Pr. 11, Pr. 12
Multi-speed operation
Pr. 1, Pr. 2, Pr. 4, Pr. 5, Pr. 6, Pr. 15, Pr. 24, Pr. 25, Pr. 26, Pr. 27,
Pr. 160
Jog operation
Pr. 15, Pr. 16
Frequency jump operation
Pr. 31, Pr. 32, Pr. 33, Pr. 34, Pr. 35, Pr. 36
Automatic restart after instantaneous power failure
Pr. 57, Pr. 58
Rel
a
ted t
o
operat
io
n
Optimum acceleration/deceleration within continuous
rating range
Pr. 60
To perform commercial power supply
↔
inverter
switch-over operation
Pr. 135 to Pr. 139, Pr. 160, Pr. 180 to Pr. 186,
Pr. 190 to Pr. 195
Timing of magnetic brake operation
Pr. 42, Pr. 160, Pr. 190 to Pr. 195
Reversible operation according to analog signal
polarity
Pr. 28, Pr. 73
Sub-motor operation
Pr. 0, Pr. 3, Pr. 7, Pr. 8, Pr. 44, Pr. 45, Pr. 46, Pr. 47
To make desired output characteristics
Pr. 100 to Pr. 109
Operation via communication with personal computer
Pr. 117 to Pr. 124, Pr. 160
Operation under PID control
Pr. 73, Pr. 79, Pr. 128 to Pr. 134, Pr. 160,
Pr. 180 to Pr. 186, Pr. 190 to Pr. 195
Advanced PID control
(NA, EC versions only)
Pr. 128, Pr. 130 to Pr. 134, Pr. 180 to Pr. 186, Pr. 190 to Pr. 195,
(Pr. 320 to Pr. 322), Pr. 500 to Pr. 516
To make backlash compensation
Pr. 140 to Pr. 143
Rel
a
ted t
o
appl
ic
at
ion operat
io
n
To suppress noise
Pr. 72, Pr. 240
Calibration of frequency meter
Pr. 54, Pr. 55, Pr. 56, Pr. 158, Pr. 160, Pr. 900, Pr. 901
Adjustment of digital frequency meter
Pr. 54, Pr. 55, Pr. 56, Pr. 900
Display of speed, etc.
Pr. 37, Pr. 52, Pr. 53, Pr. 160
Clearing of inverter's actual operation time
Pr. 171
Rel
a
ted t
o
m
oni
to
ri
ng
Alarm code output selection
Pr. 76
Function rewrite prevention
Pr. 77
Reverse rotation prevention
Pr. 78
To group parameters
Pr. 160, Pr. 173 to Pr. 176
Rel
a
ted t
o
in
c
o
rr
e
c
t
operat
io
n
prevent
io
n
To set initial values for parameters
Pr. 199
Assignment of input terminal functions
Pr. 180 to Pr. 186
Assignment of output terminal functions
Pr. 190 to Pr. 195
To increase cooling fan life
Pr. 244
Motor overheat protection
Pr. 9, Pr. 71
Automatic restart after alarm stop
Pr. 65, Pr. 67, Pr. 68, Pr. 69
Selection of key beep
Pr. 990
Inverter reset selection
Pr. 75
Ot
hers
Output phase failure protection selection
Pr. 251
4