![Mitsubishi Electric FR-F500 Series Скачать руководство пользователя страница 76](http://html.mh-extra.com/html/mitsubishi-electric/fr-f500-series/fr-f500-series_instruction-manual_239240076.webp)
PARAMETERS
63
Func-
tion
Parameter
Number
Name
Setting Range
Minimum
Setting
Increments
Factory
Setting
〈〈〈〈
EC
Version
〉〉〉〉
Refer
To
Page:
Cust-
omer
Set-
ting
41
Up-to-frequency sensitivity
0 to 100%
0.1%
10%
85
42
Output frequency detection
0 to 120Hz
0.01Hz
6Hz
86
Out
put
te
rm
inal
func
ti
ons
43
Output frequency detection for reverse
rotation
0 to 120Hz, 9999
0.01Hz
9999
86
44
Second acceleration/deceleration time
0 to 3600 s/
0 to 360 s
0.1 s/0.01 s
5 s
72
45
Second deceleration time
0 to 3600 s/0 to 360 s,
9999
0.1 s/0.01 s
9999
72
46
Second torque boost
0 to 30%, 9999
0.1%
9999
68
47
Second V/F (base frequency)
0 to 120Hz, 9999
0.01Hz
9999
70
48
Second stall prevention operation current
0 to 150%
0.1%
120%
87
49
Second stall prevention operation
frequency
0 to 120Hz, 9999
0.01Hz
0
87
Sec
ond f
unc
ti
ons
50
Second output frequency detection
0 to 120Hz
0.01Hz
30Hz
86
$
52
DU/PU main display data selection
0, 5, 6, 8, 10 to 14, 17,
20, 23, 24, 25, 100
1
0
88
$
53
PU level display data selection
0 to 3, 5, 6, 8, 10 to 14,
17
1
1
88
$
54
FM terminal function selection
1 to 3, 5, 6, 8, 10 to 14,
17, 21
1
1
88
$
55
Frequency monitoring reference
0 to 120Hz
0.01Hz
60Hz
〈
50Hz
〉
90
D
isp
la
y
fu
n
cti
o
n
s
$
56
Current monitoring reference
0 to 500A
0.01A
Rated
output
current
90
$
57
Restart coasting time
0, 0.1 to 5 s, 9999
0.1 s
9999
91
A
u
to
ma
ti
c
res
ta
rt
func
ti
ons
$
58
Restart cushion time
0 to 60 s
0.1 s
1.0 s
91
Addit
ional
fu
n
cti
o
n
59
Remote setting function selection
0, 1, 2
1
0
93
$
60
Intelligent mode selection
0, 3, 4, 9
1
0
95
61
Reference I for intelligent mode
0 to 500A, 9999
0.01A
9999
96
62
Ref. I for intelligent mode accel.
0 to 150%, 9999
0.1%
9999
96
63
Ref. I for intelligent mode decel.
0 to 150%, 9999
0.1%
9999
96
$
65
Retry selection
0 to 5
1
0
97
$
66
Stall prevention operation level reduction
starting frequency
0 to 120Hz
0.01Hz
60Hz
〈
50Hz
〉
79
$
67
Number of retries at alarm occurrence
0 to 10,101 to 110
1
0
97
$
68
Retry waiting time
0 to 10 s
0.1 s
1 s
97
$
69
Retry count display erasure
0
0
97
$
71
Applied motor
0, 1, 2
1
0
99
$
72
PWM frequency selection
0 to 15
1
2
100
$
73
0-5V/0-10V selection
0 to 5, 10 to 15
1
1
101
$
74
Filter time constant
0 to 8
1
1
102
$
75
Reset selection/disconnected PU
detection/PU stop selection
0 to 3, 14 to 17
1
14
102
$
76
Alarm code output selection
0, 1, 2
1
0
104
$
77
Parameter write disable selection
0, 1, 2
1
0
105
$
78
Reverse rotation prevention selection
0, 1,
1
0
106
Operat
ion s
e
lec
ti
on f
unc
ti
ons
$
79
Operation mode selection
0 to 4, 6 to 8
1
0
107
100
V/F1 (first frequency)
0 to 120Hz, 9999
0.01Hz
9999
110
101
V/F1 (first frequency voltage)
0 to 1000V
0.1V
0
110
102
V/F2 (second frequency)
0 to 120Hz, 9999
0.01Hz
9999
110
103
V/F2 (second frequency voltage)
0 to 1000V
0.1V
0
110
104
V/F3 (third frequency)
0 to 120Hz, 9999
0.01Hz
9999
110
105
V/F3 (third frequency voltage)
0 to 1000V
0.1V
0
110
5-point
f
lex
ible V/
F
ch
a
ra
cte
ri
sti
cs
106
V/F4 (fourth frequency)
0 to 120Hz, 9999
0.01Hz
9999
110
Parameter List
4
Содержание FR-F500 Series
Страница 221: ......