PARAMETERS
96
Pr. 60 "intelligent mode selection"
Related parameter
4.2.27 Acceleration/deceleration reference current (Pr. 61 to Pr. 63)
Pr. 61 "Reference I for intelligent mode"
Pr. 62 "Ref. I for intelligent mode accel"
Pr. 63 "Ref. I for intelligent mode decel"
#
Set these parameters to improve performance in the intelligent mode.
#
Pr. 61 to Pr. 63 are only valid when any of "3" or "4" is selected for Pr. 60.
Parameter
Number
Factory
Setting
Setting Range
Remarks
61
9999
0 to 500A, 9999
9999: Referenced from rated inverter
current.
62
9999
0 to 150%, 9999
63
9999
0 to 150%, 9999
<Setting>
(1) Pr. 61 "Reference I for intelligent mode"
Setting
Reference Current
9999 (factory setting)
Referenced from rated inverter current
0 to 500A
Referenced from setting (rated motor current)
(2) Pr. 62 "Ref. I for intelligent mode accel"
The reference current setting at acceleration can be changed.
Setting
Reference Current
9999 (factory setting)
100% is the optimum value.
0 to 150%
The setting of 0 to 150% is the optimum
value.
(3) Pr. 63 "Ref. I for intelligent mode decel "
The reference current setting at deceleration can be changed.
Setting
Reference Current
9999 (factory setting)
100% is the optimum value.
0 to 150%
The setting of 0 to 150% is the optimum
value.
Содержание FR-F500 Series
Страница 221: ......