OPTIONS
196
Name
Type
Application, Specifications, etc.
Applicable
Inverter
Manual controller
FR-AX (Note 4)
For independent operation. With frequency meter,
frequency setting potentiometer and start switch.
DC tach. follower
FR-AL (Note 4)
For joint operation using external signals. (0 to
5VDC, 0 to 10VDC) (1VA) (Note 2)
Three speed selector
FR-AT (Note 4)
For three-speed (high, middle, low) switching
operation. (1.5VA)
Motorized speed setter
FR-FK (Note 4)
For remote operation. Allows operation to be
controlled from several places. (5VA)
Ratio setter
FR-FH (Note 4)
For ratio control. Allows ratios to be set to five
inverters. (3VA)
PG follower (Note 4)
FR-FP
For follow-up operation using the signal of a pilot
generator (PG). (2VA)
Master controller (Note 4)
FR-FG
For parallel operation of several (up to 35)
inverters. (5VA)
Soft starter (Note 4)
FR-FC
For soft start and stop. Allows parallel operation
and acceleration/deceleration. (3VA)
Deviation detector (Note 4)
FR-FD
For synchronous operation. Used with a deviation
sensor and synchro. (5VA)
Preamplifier (Note 4)
FR-FA
Can be used as A/V conversion or operational
amplifier. (3VA)
Pilot generator (Note 4)
QVAH-10
For follow-up operation. 70/35VAC 500Hz (at
2500r/min)
Deviation sensor (Note 4)
YVGC-500W-NS
For synchronous operation (mechanical deviation
detection). Output 90VAC/90
°
Frequency setting
potentiometer (Note 4)
WA2W 1k
Ω
For frequency setting. Wire-wound type. 2W 1K
Ω
B characteristic.
Frequency meter (Note 4)
YM206NRI 1mA
Dedicated frequency meter (up to 120Hz scale).
Moving-coil DC ammeter.
Calibration resistor (Note 4)
RV24YN 10k
Ω
For calibration of the frequency meter. Carbon-film
type. B characteristic.
Inverter setup software
FR-SW
"
-SETUP-
WE
Supports steps from inverter start-up to
maintenance. (WJ is Japanese version.)
Common to
all models
Note: 1. "H" in the type code indicates 400V class.Power supply specifications of FR series controllers
and setters: 200VAC 50Hz, 200V/220VAC 60Hz, 115VAC 60Hz.
2. Rated power consumption
3. The intercompatibility attachment (FR-A5AT
""
) is required to mount the inverter, with the
exception of some models.
4. Options available in Japan only.
5. For the FR-CV (Power Regeneration Common Converter), –AT in the type code indicates a
model for installation inside an enclosure. The model without the –AT type code indicates a
model with a heatsink outside mounting structure. Since the structure for the 37K or more
capacities can be converted into either model by changing the feet positions, –AT is not included
in the type code for the 37K or more capacities.