APPENDICES
200
Data Codes
Func-
tion
Parameter
Number
Name
Read
Write
Link Parameter Extension
Setting (Instruction code 7F/FF)
140
Backlash acceleration stopping frequency
28
A8
1
141
Backlash acceleration stopping time
29
A9
1
142
Backlash deceleration stopping frequency
2A
AA
1
Ba
ckl
a
s
h
143
Backlash deceleration stopping time
2B
AB
1
144
Speed setting switch-over
2C
AC
1
Di
s
-
pl
ay
145
PU display language selection
2D
AD
1
148
Stall prevention operation level at 0V input
30
B0
1
A
ddi
ti
onal
func
ti
ons
149
Stall prevention operation level at 10V input
31
B1
1
152
Zero current detection level
34
B4
1
Current
det
ec
tion
153
Zero current detection period
35
B5
1
154
Voltage reduction selection during stall
prevention operation
36
B6
1
155
RT activated condition
37
B7
1
156
Stall prevention operation selection
38
B8
1
157
OL signal output waiting time
39
B9
1
S
ub f
unc
ti
ons
158
AM terminal function selection
3A
BA
1
A
ddi
ti
onal
func
ti
on
160
User group read selection
00
80
2
162
Automatic restart after instantaneous power
failure selection
02
82
2
163
First cushion time for restart
03
83
2
164
First cushion voltage for restart
04
84
2
Res
tart
af
te
r
in
s
tant
aneous
pow
er f
a
ilu
re
165
Restart stall prevention operation level
05
85
2
170
Watt-hour meter clear
0A
8A
2
In
itia
l
m
oni
to
r
171
Actual operation hour meter clear
0B
8B
2
173
User group 1 registration
0D
8D
2
174
User group 1 deletion
0E
8E
2
175
User group 2 registration
0F
8F
2
Us
er
func
ti
ons
176
User group 2 deletion
10
90
2
180
RL terminal function selection
14
94
2
181
RM terminal function selection
15
95
2
182
RH terminal function selection
16
96
2
183
RT terminal function selection
17
97
2
184
AU terminal function selection
18
98
2
185
JOG terminal function selection
19
99
2
186
CS terminal function selection
1A
9A
2
190
RUN terminal function selection
1E
9E
2
191
SU terminal function selection
1F
9F
2
192
IPF terminal function selection
20
A0
2
193
OL terminal function selection
21
A1
2
194
FU terminal function selection
22
A2
2
Term
inal
as
s
ignm
ent
f
unc
ti
ons
195
A, B, C terminal function selection
23
A3
2
A
ddi
ti
onal
func
ti
on
199
User's initial value setting
27
A7
2
Содержание FR-F500 Series
Страница 221: ......