Adjus
tment
function
820
Speed control P gain 1
0 to 1000%
1%
25%
821
Speed control integral time 1
0 to 20s
0.001s
0.333s
—
870
Speed detection hysteresis
0 to 5Hz
0.01Hz
0Hz
Pr
otect
ive
functio
ns
872
Input phase loss protection selection
0, 1
1
0
Re
generation
avoidance function
882
Regeneration avoidance operation
selection
0 to 2
1
0
883
Regeneration avoidance operation
level
300 to 800V
0.1V
400/780V
885
Regeneration avoidance compensation
frequency limit value
0 to 30Hz, 9999
0.01Hz
6Hz
886
Regeneration avoidance voltage gain
0 to 200%
0.1%
100%
Fr
ee
pa
ra
m
et
e
r
888
Free parameter 1
0 to 9999
1
9999
889
Free parameter 2
0 to 9999
1
9999
Energy saving monitor
891
Cumulative power monitor digit shifted times 0 to 4, 9999
1
9999
892
Load factor
30 to 150%
0.1%
100%
893
Energy saving monitor reference (motor
capacity)
0.4 to 15kW
0.01kW
Rated
inverter
capacity
894
Control selection during commercial power-
supply operation
0 to 3
1
0
895
Power saving rate reference value
0, 1, 9999
1
9999
896
Power unit cost
0 to 500, 9999
0.01
9999
897
Power saving monitor average time
0, 1 to 1000h, 9999
1h
9999
898
Power saving cumulative monitor clear
0, 1, 10, 9999
1
9999
899
Operation time rate (estimated value)
0 to 100%, 9999
0.1%
9999
C
alibration p
arameter
s
C0
(900)
FM terminal calibration
—
—
—
C2
(902)
Terminal 2 frequency setting bias
frequency
0 to 400Hz
0.01Hz
0Hz
C3
(902)
Terminal 2 frequency setting bias
0 to 300%
0.1%
0%
125
(903)
Terminal 2 frequency setting gain
frequency
0 to 400Hz
0.01Hz
60Hz
C4
(903)
Terminal 2 frequency setting gain
0 to 300%
0.1%
100%
C5
(904)
Terminal 4 frequency setting bias
frequency
0 to 400Hz
0.01Hz
0Hz
C6
(904)
Terminal 4 frequency setting bias
0 to 300%
0.1%
20%
126
(905)
Terminal 4 frequency setting gain
frequency
0 to 400Hz
0.01Hz
60Hz
C7
(905)
Terminal 4 frequency setting gain
0 to 300%
0.1%
100%
C22
(922)
Frequency setting voltage bias
frequency (built-in potentiometer)
0 to 400Hz
0.01Hz
0Hz
C23
(922)
Frequency setting voltage bias (built-in
potentiometer)
0 to 300%
0.1%
0%
C24
(923)
Frequency setting voltage gain
frequency (built-in potentiometer)
0 to 400Hz
0.01Hz
60Hz
C25
(923)
Frequency setting voltage gain (built-in
potentiometer)
0 to 300%
0.1%
100%
Func-
tion
Parameter
Name
Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting