An IPM (interior permanent magnet) motor is a highly efficient motor compared to a general-purpose motor. Highly
efficient motor control and highly accurate motor speed control can be performed by using the inverter with an IPM
motor.
For the motor model, dedicated IPM motor (MM-EFS model or MM-EF model) must be used.
The motor capacity must be equivalent to the inverter capacity.
Single-motor operation (one motor run by one inverter) must be performed.
The overall wiring length with the motor must be within the specified value.
(Refer to page 71)
This inverter is set for a general-purpose motor in the initial setting. Follow the following procedure to change the
setting for the IPM motor control.
IPM motor (MM-EFS) control setting from the operation panel (parameter setting mode)
998, IPM
IPM motor control, IPM parameter initialization
Pr.998 IPM parameter initialization
IPM IPM parameter initialization
Setting procedure of IPM motor control
POINT
The parameters required to drive an IPM motor are automatically changed as a batch.
To switch to the IPM motor control, initialize the parameter settings in the parameter setting mode or by setting
Pr.998
. If
parameter initialization is performed after setting other parameters, some of those parameters will be initialized too.
(Refer to the next page for the parameters initialized with this operation.)
Operation
Display
1. Screen at power-ON
The monitor display appears.
2. Parameter setting mode
Press
to choose the parameter setting
mode.
3. Selecting the parameter
Turn
until
(IPM
parameter
initialization) appears.
4. Displaying the setting
Press
to read the currently set value.
"
" (initial value) appears.
5. Selecting the setting
Turn
to change it to the set value
"
"
6. Parameter setting
Press
to set.
Flicker ... Parameter setting complete!!
Setting
Description
0
Parameter settings for a general-purpose motor
1
Parameter settings for a high-efficiency IPM motor MM-EF (rotations per minute)
12
Parameter settings for a premium high-efficiency IPM motor MM-EFS (rotations per minute)
REMARKS
Performing IPM parameter initialization in the parameter setting mode of the operation panel automatically changes the
Pr.998
IPM parameter initialization
setting.
To check the control method (general-purpose motor control/IPM motor control), simply press the setting dial while the monitor
screen is displayed.
(Refer to page 21)
The IPM parameter setting is displayed as "1, 12" in the parameter setting mode even if
Pr.998 IPM parameter initialization
=
"101, 112."
IPM
IPM
IPM
The parameter
number read
previously appears.
IPM Motor Control