67
Surge voltage
suppression filter
FR-BMF-H
K
Limits surge voltage applied to motor terminals when driving a 400V class motor with an inverter (available only with general-purpose motors).
Supports FR-F740PJ-5.5K to 37K.
Specification
Connection diagram
Outline dimension
Name (model)
Specification and Structure
Model FR-BMF-H
K
7.5
15
Applicable motor
capacity (kW)
5.5
7.5
11
15
Rated current (A)
17
31
Overload current
rating
150 60s 200 0.5s (inverse-time characteristics)
Rated input AC
voltage
Three-phase 380 to 480V
Permissible AC voltage
fluctuation
323 to 528V
Maximum frequency
120Hz
PWM carrier frequency
2kHz or less
Protective structure
(JEM 1030)
Open type (IP00)
Cooling system
Self-cooling
Maximum wiring length
100m or shorter
Approx. mass (kg)
5.5
9.5
Envir
o
n
m
ent
Surrounding air
temperature
-10°C to +50°C (non-freezing)
Ambient humidity
90% RH or less (non-condensing)
Atmosphere
Indoors (free from corrosive gas, flammable gas,
oil mist, dust and dirt)
Altitude/vibration
Maximum 1000m above sea level, 5.9m/s
2
or
less
at 10 to 55Hz (directions of X, Y, Z axes)
Indicates the maximum capacity applicable with the Mitsubishi 4-pole standard motor.
Determined by the specification of the connected inverter (400V class).
Set
Pr.72 PWM frequency selection
to 2kHz or less.
When an inverter has a filter mounted on its back, do not use such an inverter on a moving object or in a place that vibrates (exceeding 1.96m/s
2
).
R
S
T
X
Y
Z
TH0
TH1
FR-BMF
Motor
within 100m
M
U
V
W
Inverter
∗
Install a stepdown transformer.
MCCB
MC
Three-phase
AC power
supply
T
∗
ON
MC
OFF
MC
7.5
7.5
60
149.5
325
340
325
370
Crimping terminal 5.5-4
6
2.3
Isolation cap color
Main terminal block (M4)
Control terminal block (M3)
(U)
Red
Blue
(W)
(V)
White
2.3
6
195
208
150
230
4-M4
4-M5
245
138
13.5
75
45
Terminal layout
TH0 TH1
10
165
80
285
380
500
480
2-
φ
10 hole
205
Main terminal block (M5)
Control terminal block (M3)
2.3
420
2.3
Crimping terminal: 8-6
10
180
260
195
230
6-M5
4-M8
245
457
33
10
31
100
50
Terminal layout
TH0 TH1
Earth terminal
(M6)
FR-BMF-H15K
FR-BMF-H7.5K
(Unit: mm)
Isolation cap color
(U)
Red
Blue
(W)
(V)
White
X Y Z
X Y Z
Rating plate
Rating
plate
2-
φ
6 hole
Earth terminal (M6)