1424-EN/LZT103 089 D1 2016-03-04
Mitel DT4x3 Cordless Phones for MiVoice MX-ONE
83
LED Error Indications
See also chapter
LED Indications during Easy Replacement
on page 79.
LED is flashing red, quick flash, (100 ms on, 800 ms off)
1) If a third handset, that is another handset than the "old" (the replaced handset) and
"new" (the replacement handset) handset, is inserted into the charger during Easy
Replacement, this error indication appears. Change to the correct handset.
2) The charger has found that Easy Replacement does not work. Change back to the
"new" handset.
LED is flashing red, long flash (800 ms on, 100 ms off)
Error during Easy Replacement. Both handsets need to be sent for service.
SERVICE NEEDED
Parameters corrupt.
Note:
This display
message is only
shown in English.
The handset is defective.
Select reset option on the
middle soft key if available or
if no reset option is available
or fault does not resolve the
handset needs repair. Note:
Display message only shown
in English.
Enter PIN code
The handset’s lock is activated. Enter the required PIN code.
If PIN code lost enter new via
PDM or do a factory reset via
PDM.
Battery low, charge
now
The battery level is low.
Charge or replace the battery.
Phonebook is not
available at the
moment.
The phonebook does not
respond, not available at the
moment.
Try again later or if fault
persists do a factory reset via
admin menu or PDM.
Voice mail number not
defined
There is no Voice mail number
defined in the handset.
Define a Voice mail number
via PDM.
Could not encrypt
connection
The parameter "Encryption
Required" is enabled in the
handset in combination with;
1) Unencrypted base station(s);
and/or,
2) Unsupported base station(s).
1) Disable the "Encryption
required" parameter in
handset via PDM; and/or,
2) Enable the encryption in
the base station(s); and/or,
3) Use supported base
station(s). Ask your supplier.
Not allowed
2) The extension (User) does not
exists.
3) The password is not correct.
2) Make sure that you entered
correct extension. If needed,
contact the system
administrator.
3) Make sure that you have
entered correct password.
Ask the system administrator
if you have forgot the
password.