7.13 Totalizing applications
With this "Totalizing" application, you can add weights to the totalizing memory. In
addition to weight values, the number of separate values added to memory is also saved.
Menu [APPLIC.] - [APPLIC.3] - [TOTALIZ] (see chapter
).
Features
-
You can weigh up to 999 items.
-
Save values automatically: Simultaneous saving of net values and calculated values (if
available).
Setting: [APPLIC.] - [APPLIC.3] - [TOTALIZ] - [AUTO.SAV] (3.16) (see chapter
-
Save weight values and calculated values from either Application 1 (for example,
Counting, Weighing in Percent) or Application 2 (Checkweighing).
Setting: [APPLIC.] - [APPLIC.3] - [TOTALIZ] - [VAL.FROM] (3.22) (see chapter
).
-
Current transaction number displayed in the number display (indicating the
transactions already added)
-
Weighing in up to a deined target, with the totalization memory c current
weight displayed in the text lines
-
Save weight values manually or automatically
-
Accurate calculation of total of weight values from two weighing platforms
-
Activate Info mode via the
key
-
Automatic printout when value saved
-
Automatic taring of container weight
Setting: [APPLIC.] - [AUT.TARE] (3.7) (see chapter
7.13.1
Exit application, delete parameters
The value of the reference sample weight in the reference memory remains active until it
is deleted via the
key or overwritten or until the application is changed.
The reference sample weight also remains saved after the scale is turned of. You can
assign diferent functions to the
key for deleting applications. When you clear
applications, you can delete either the data stored for all applications or just selected data
stored for the active application.
Setting: [APPLIC.] - [CLER.CF] (3.24) (see chapter
7.13.2
Tare function
If you store a tare (weight value) by pressing the
key, you can later enter a tare value
manually. The tare value you enter is added to the stored tare value.
Setting: [APPLIC.] - [TARE.FNC] - [NORMAL] (3.25.1) (factory setting) (see chapter
).
A tare value entered manually overwrites a stored tare value (weight value). If you enter a
tare value manually, a tare value (weight value) stored later overwrites the manually
entered value.
Setting: [APPLIC.] - [TARE.FNC] - [SPECIAL] (3.25.2) (see chapter
Combics 2 Series Complete Scales Models CAW2P, CAW2S
7 Operating
EN-152
Minebea Intec
Содержание CAW2P
Страница 205: ...Typ Waage Minecomb Typ Auswerteger t TA EG Bauartzulassung T11379 Pr fschein D09 11 02 Typ Minecomb...
Страница 206: ...Typ Waage Minecomb Typ Auswerteger t TA EG Bauartzulassung T11379 Pr fschein D09 11 02...
Страница 207: ...Option Y2 Typ Waage Minecomb Typ Auswerteger t TA EG Bauartzulassung T11379 Pr fschein D09 11 02...
Страница 209: ...CAW3S1 60FE NCE Typ Waage Minecomb Typ Auswerteger t TA EG Bauartzulassung T11379 Pr fschein D09 11 02...
Страница 210: ......
Страница 211: ......
Страница 213: ......
Страница 214: ......
Страница 215: ......
Страница 220: ......
Страница 222: ......
Страница 223: ......