Armature filters
If the end-user is not using a CE-approved motor, a second filter,
part no. CExxMM, must be used on the armature. XX = rated
current of the filter. Minarik Filters are listed below.
Table 3. Minarik Filters
Nameplate Current of
Minarik Filter
Motor Wired to the Drive
Part Number
0 to 4 amps
CE4MM
4.1 to 13 amps
CE20MM
The filters listed above are Real-Pole Balanced-Pi 3-pole
filters. If the exact filter is not available, the specifications are
as follows:
L & L1 = 2 x (0.8) milliHenries.
C & C1 = 2 x (0.1) microFarads @ 400W VDC.
Rin = 0.1 ohm; Rout = 1.2 ohm.
The filters listed above must be wired to the DC output of the
drive, as close to the drive as possible.
38