37
CE Compliance
Line filters
Minarik requires the Corcom® line filters listed below.
Table 2. Corcom® Filters
Nameplate Current of
Corcom® Filter
Motor Wired to the Drive
Part Number
0 to 4 amps
6VV1
4.1 to 13 amps
20VV1
If the exact line filter is not available, the specifications are as
follows:
L = 1.8 milliHenries.
C = 0.01 microFarads (line-to-ground); 1.1 microFarads (line-
to-line).
R = 330Kohms.
Rated current: 1.4 times maximum DC motor current.
Filter type: Balanced 2-section.
The line filters should be wired to the AC line within 0.25 meters
of the drive. The ground connection from the line filter must be
wired to solid earth ground (resistance less than 500 ohms); not
machine ground. This is very important!
If the end-user is using a CE-approved motor, the correct line
filter listed above is all that is necessary to meet the EMC
directives listed herein.