33
Troubleshooting
Line fuse blows.
1. Line fuse is the wrong
size.
2. Motor cable or armature
is shorted to ground.
3. Nuisance tripping
caused by a combination
of ambient conditions
and high-current spikes
(i.e. reversing).
1. Check that the line fuse
is correct for the motor
size.
2. Check motor cable and
armature for shorts.
3. Add a blower to cool the
drive components;
decrease TORQUE
settings,
or
resize motor
and drive for actual load
demand,
or
check for
incorrectly aligned
mechanical components
or “jams”.
Problem
Possible
Causes
Suggested
Solutions
All manuals and user guides at all-guides.com