11
Inhibit terminals
Short the INHIBIT terminals to coast the motor to minimum
speed (see Figure 7 for INHIBIT terminal location). Reopen the
INHIBIT terminals to accelerate the motor to set speed.
Twist inhibit wires and separate them from other power-carrying
wires or sources of electrical noise. Use shielded cable if the
inhibit wires are longer than 18 inches (46 cm). If shielded cable
is used, ground only one end of the shield to earth ground. Do not
ground both ends of the shield.
Minarik Corporation offers two accessory plug harnesses for
connecting to the INHIBIT terminals: part number 201-0024
[inhibit plug with 18 inches (46 cm) leads]; and part number
201-0079 [inhibit plug with 36 inches (91 cm) leads].
Figure 7. INHIBIT Terminals