26
Application Notes
RUN/JOG switch
Using a RUN/JOG switch is recommended in applications where
quick stopping is not needed and frequent jogging is required.
Use a single pole, two position switch for the RUN/JOG switch,
and a single pole, normally closed, momentary operated
pushbutton for the JOG pushbutton.
In the first wiring option, connect the RUN/JOG switch and JOG
pushbutton to the inhibit plug as shown in Figure 15. The motor
coasts to a stop when the RUN/JOG switch is set to JOG. Press
the JOG pushbutton to jog the motor. Return the RUN/JOG
switch to RUN for normal operation.
In the second wiring option, connect the RUN/JOG switch and
the JOG pushbutton as shown in the Figure 16. When the
RUN/JOG switch is set to JOG, the motor decelerates to
minimum speed (minimum speed is determined by the MIN SPD
trimpot setting). Press the JOG pushbutton to jog the motor.
Return the RUN/JOG switch to RUN for normal operation.