Filter (CODE 102915, supplied as an optional part, refer to chapter 5.2) 

In the event of connection to the filter, the Ventilation system connected to the unit must compensate for the 
550Pa pressure drop of the filter. 
- Dimensions: LxDxH 618mmx780mmx1450mm (24.3

’’x30.7’’x57’’) 

- Infeed and outfeed dimensions Ø: 200mm (7.9in) 
- Weight: 72kg (158.7lb) 
 

Fixative loading/unloading system: 

-  Container  transport  trolley  in  stainless  steel  (dimensions:  LxDxH  350  x  500  x  750mm  -  13.8x19.7x29.5in, 
dimensions  container  housing  base:  470  x  320mm  -  18.5x12.6in,  max  container  height  400mm-15.8in), 
equipped with a containment tank for any spills (capacity: 0.55 litres), a grille and a retainer for the container 
- Fixative dispenser with pedal control 

“Used fixative” container cap equipped with “full container” sensor and fume extraction system (threading 

type S55) 
- Cap for "new fixative" container (S55 threading). This container is not supplied with the unit. 
- The work surface is equipped with a recessed funnel for draining the used fixative in the dedicated container 
including the filter 
 
 

Auxiliary sockets 

- For connecting instruments/optional parts (such as printers, scales, etc.) 
- 2 type sockets IEC 320 C13 230Watt/1A max total 
 

Environmental conditions: 

-Operating temperature: 15°C

–30°C (59°F-86°F) 

-Relative humidity: 10°C - 80% without condensation 
-Altitude:  up to 2000m (78.7in) 
-Maximum temperature of contact surfaces:  lower 40°C (104°F) 
 
 
 
 

1.4.  Compatible reagents 

 
Water, ethanol, formaldehyde 10% volume/volume (4% weight/weight), zinc formalin (no chloride), FineFIX, 
alcohol-based fixatives, inks. 
 

 
 

 

 

It is necessary to connect the unit to a fume extraction system. 

 

 

 

Output air flow rate: 1200 m³/h ± 100 m³/h. 
The system must allow for a flow rate of at least 1300m³/h in case is not present one of the 
two filters provided as optional part (refer to chapters 5.2 and 5.3). 

 

Do not use overly acidic reagents (pH <4). 

 

 

 

DO NOT USE ANY REAGENTS OTHER THAN THOSE LISTED ABOVE. 
For 

any 

doubts, 

please 

contact 

us 

at 

the 

following 

address: 

[email protected]

. 

Содержание eGROSS

Страница 1: ...eGROSSpro x eGROSS ErgonomicWorkstation for histopathology OperatorManual MM137 MILESTONE H E L P I N G P A T I E N T S...

Страница 2: ......

Страница 3: ...his operator manual and to always keep it within reach for convenient and quick referencing For any clarification or request for assistance please contact our representative in your country You can al...

Страница 4: ...the eGROSS pro x unit 67 4 2 1 Germicidal efficacy of polyphenol based disinfectant agents 68 4 2 2 General operating procedure 69 4 2 2 a Keyboard and mouse 70 4 2 2 b Foot pedal control 70 4 2 2 c T...

Страница 5: ...eGROSS pro x eGROSS MM137 004 Operator Manual 5 6 1 Return for repair to Manufacturer 93 7 DISPOSING OF THE UNIT 94...

Страница 6: ...ic shock Biohazard be careful when you execute the procedure marked with this symbol danger of biohazard contamination Biological hazard pay attention when performing a procedure marked with this symb...

Страница 7: ...the working area Concealed keyboard Weight 265kg 584lb Structure Stainless steel work surface Vented work surface with washable compartment below Blue cutting board for downdraft aspiration downward...

Страница 8: ...cy regulations to be checked before enabling this function Dimensions LxHxD 470 5 x 415 2 x 75 6mm 18 52 x 16 34 x 2 97 Weight 7 4kg 16 3lb PC power supply 18V DC 5 55A MAX available I O see the pictu...

Страница 9: ...part of the PC 1 Switch On button 2 Enable disable touch screen 3 Volume 4 Light 5 Switch On reading lights button At the installation carefully remove the film present on the screen It is suggested t...

Страница 10: ...d with a set of 3 lenses with different close up levels 1 1 3 1 5 Weight 2 8 kg 6 1lb 250g camera power supply Built in LED lighting Dimensions 137 x 162 x 211mm 5 39 x 6 37 x 8 30 USB data cable leng...

Страница 11: ...ing 2000 Lux with environmental conditions of 400 Lux and all the Unit lights switched on with Hepta lamp provided as optional part as shown into the chapter 5 6 Distance 50cm 30000 lux illuminated ar...

Страница 12: ...This container is not supplied with the unit The work surface is equipped with a recessed funnel for draining the used fixative in the dedicated container including the filter Auxiliary sockets For c...

Страница 13: ...zational measures to ensure that the personal data are not attributed to an identified or identifiable natural person Equipment shall be connected to main sockets outlets which is accessible and visib...

Страница 14: ...ain support from Milestone connect the PC to Internet then contact customer support at customersupport milestonemedsrl com and communicate these data Serial number of the unit version of the remote co...

Страница 15: ...following images eGROSS pro x eGROSS The Milestone eGROSS pro x eGROSS unit is a precision instrument that must be unpacked and installed with the utmost care Make sure that the unit is at level and...

Страница 16: ...Width 185cm 72 8in Height 152cm 59 8in min 182cm 71 7in max Depth 81cm 31 9in 87cm 34 3in with trolley Dimensions of space required for positioning the unit to be added to the dimensions of the unit...

Страница 17: ...s carefully before using the eGROSS pro x eGROSS unit Upon opening the crate check to make sure that all the parts are at present eGROSS pro x eGROSS includes DESCRIPTION IMAGE eGROSS pro x eGROSS 1 C...

Страница 18: ...SS pro x eGROSS 4 2 Flexible mixer hoses 3 8 1 2 X X 5 Fixative loading pedal Code 102884 X X 6 Container transport trolley complete with tray Code 102636 drainage grille and container retainer Code 1...

Страница 19: ...37 004 Operator Manual 19 DESCRIPTION IMAGE eGROSS pro x eGROSS 8 Fixative drain funnel filters Code 102862 Code 102671 X X 9 Ink tray Code 102725 X X 10 Work area screen Code 102819 X X 11 Wash basin...

Страница 20: ...RIPTION IMAGE eGROSS pro x eGROSS 12 Lateral screens Code 102761 X X 13 Downdraft tray Code 102783 complete with net removable Code 102784 X X 14 Wash basin cover Code 102782 X X 15 2 filters for the...

Страница 21: ...rator Manual 21 DESCRIPTION IMAGE eGROSS pro x eGROSS 16 Set of Allen screws CODE 102138 X X 17 Foot pedal Code 370033 X 18 Waterproof disinfectable keyboard Code 372352 X 19 Sizing Ruler Code 40219 X...

Страница 22: ...erator Manual 22 DESCRIPTION IMAGE eGROSS pro x eGROSS 21 Pole for the camera X 22 Set of 3 lenses with different zooms 1 mounted on the camera CODE 370554 X 23 19 Point of care touchscreen control te...

Страница 23: ...lete with extension cable CODE 370039 X 26 Touch Pen CODE 370361 there are two small black keys on the touch pen for the enter command and right click of the mouse X 27 Rear polycarbonate panel X X 28...

Страница 24: ...electronic format Recovery software 32Gb USB key Code 370260 containing MacroPATH FULL software Operating system image software X 33 Bootable 8GB USB key Code MAN EGROSS containing Operator manual in...

Страница 25: ...on its 5 wheels Unscrew the four support feet until the five wheels raise off the ground Therefore make sure that the unit is at level on the horizontal plane and it is slightly lean over the backsid...

Страница 26: ...tion Lateral screens There are two one to be mounted on the left side and one on the right side Both can be removed for cleaning Work area and wash basin screens There are two screens one on top of th...

Страница 27: ...between the level and the biopsy saving net placed below The figure shows the lower side of the vented surface in which the biopsy saving net is visible The following figure shows the 3 coupling point...

Страница 28: ...ink tray where you wish An example is shown in the figure Place the cutting board on the vented surface as shown below Couple the 2 feet of the cutting board in the holes of the tray only this way ve...

Страница 29: ...pro x eGROSS unit s connection to the plumbing system The figure shows the mixer tap to perform inlet water connection The figure refers to the front side of the unit If you only want to use cold wat...

Страница 30: ...temperature of the water can be adjusted by mixing the two taps hot cold water The more the taps are closed the more the water pressure may decrease Minimum pressure 1 bar maximum 10 bar To ensure op...

Страница 31: ...can be made on the back of the unit Connect the 40mm 1 57in flexible hose to the unit s drain and tighten the strap After mounting the pipe insert it into the relevant support hook Connect the opposit...

Страница 32: ...OSS pro x eGROSS unit it is possible to Empty the fixative from the containers before cutting the samples Load new fixative into the containers in which the baskets are positioned with the trays of th...

Страница 33: ...well as an upper grille and a lock for extra drain container 20L CONTAINER FOR USED FIXATIVE Position the supplied 20L empty drainage container on the trolley and secure it using the appropriate bloc...

Страница 34: ...through the dedicated pipe The air exits from the collection container through the dedicated pipe and is conveyed to the ventilation system An additional 20L container is provided as described in cha...

Страница 35: ...GROSS pro x eGROSS MM137 004 Operator Manual 35 The fixative dispenser is located above the funnel The loading of the fixative is controlled by the pedal for its assembly please refer to chapter 2 3 1...

Страница 36: ...container itself An example is shown in the figure As shown in the figure there are two pipes conveyed in the cap When the pedal is pressed the formalin comes out of a pipe of the container and then l...

Страница 37: ...neath or to the right of the unit The trolley is equipped with 4 lockable wheels all 4 of which must be locked in place by pressing the brake STOP once it has been positioned 2 3 5 Turn ON the eGROSS...

Страница 38: ...s and the polycarbonate sheet 15 countersunk M6 screws as shown in the figure below Finally assemble the Glove Holder included in the unit on the equipment holder beam Fix it with 2 nuts washers and M...

Страница 39: ...ar the nut and screw on the two nuts after positioning the two washers Finally place back the green profile The figure shows an example of the final result This concludes the eGROSS installation proce...

Страница 40: ...GROSS pro x only For packaging and transport purposes the eGROSS pro x unit is delivered without the camera PC support In order to proceed with the installation the user must have the following Pole f...

Страница 41: ...Pole cover plate To assembly the components follow the procedure below 1 Unscrew the 15 rear panel fixing screws and then remove the back panel 2 Extract the cables 3 Using the supplied Allen screws m...

Страница 42: ...ws 5 Connect the camera to its pole as explained later Using the supplied Allen screws loosen the 4 screws of the pole in the figure are indicated 2 screws in the circle the other two are on the diame...

Страница 43: ...e Unit through the two parts of the pole For this operation you can use the tubing wire already inserted into the pole Reassemble the pole avoiding to press the cables then tighten the screws Connect...

Страница 44: ...y aligning the holes 6 Using the supplied Allen screws mount the support with camera on the equipment holder beam 2 screws M8 7 Take the cables coming out the Unit and bring them to the front of the u...

Страница 45: ...the terminal support bracket on the PC 8 M4 screws Loosen the screw from the PC support Two washers will come out after removing the screw one smaller than the other 9 Using a Phillips head screwdrive...

Страница 46: ...Place the white washers yellow circle in the figure below and then insert the PC arm in the support 11 Reposition the black fairlead and tighten the M6 screw again 12 Reinstall the panel 13 Assemble t...

Страница 47: ...M137 004 Operator Manual 47 Place the plate on the rear panel of the unit in line with the arm of the camera Route all the cables in the relevant groove Now tighten the 4 M8 screws supplied to secure...

Страница 48: ...the control terminal as shown below PC CONNECTIONS USB CAMERA W28 marked in yellow USB keyboard W37 free position USB W36 marked in green connected with the USB port present on the right front panel o...

Страница 49: ...h the Glove Dispenser Follow these steps below After deciding where you want to assemble the Glove Dispenser on the beam prize to extract the green profile The distance between the nuts must correspon...

Страница 50: ...inimum Maximum None 188cm 74 infinite 200cm 78 1 66cm 25 102cm 40 95cm 37 1 3 56cm 22 79cm 31 75cm 29 1 5 50cm 19 69cm 27 65cm 25 The automatic autofocus capability of the camera depends on environmen...

Страница 51: ...evel is applied 2 4 3 Turn ON the eGROSS pro x unit At this point the eGROSS unit can be connected to its power supply using the cable on the right hand side looking at unit from the rear as shown in...

Страница 52: ...or Before attempting to use the microphone be sure to turn it on using its appropriate ON OFF button if present Barcode Reader If present this is an optional part please refer to chapter 5 connect the...

Страница 53: ...G Downdraft stainless steel working area with built in exhaust system H Wash basin with cover and hand shower tap with button control I Container holder trolley with discharge container J Fixative di...

Страница 54: ...the operator moves away from the unit As shown in the following image the sensor is placed at the centre of the ventilated surface in front of the cutting board and below the keypad The presence of t...

Страница 55: ...ation is on and therefore the Exhaust button should be pressed before pressing Manual Once the ventilation has been turned on pressing the Manual button will turn the Manual LED on too white as shown...

Страница 56: ...D is not on as the ventilation is not obstructed The AirFlow potentiometer to the right of the Exhaust LED allows you to adjust the ventilation flow rate Increase the flow rate by turning the potentio...

Страница 57: ...f the unit there is the VENTILATED WORK SURFACE WITH A WASHABLE COMPARTMENT BELOW G The work area is the only marked by black and white stripes that allows samples to be cut and photographed using the...

Страница 58: ...FRONT VIEW TOP VIEW The area where the operator is protected from the biohazard is indicated by the red line in the two previous figures and also corresponds to the area shown by the two black and wh...

Страница 59: ...the figure below the surface is turned over to show the net Insert your fingers into the 2 holes and lift the surface to access the compartment the screen above the working surface and screen above th...

Страница 60: ...sert the net respecting the 3 interlocking points shown above The surface of the compartment underneath the work surface is tilted in order to convey the liquids towards the drain The WASH BASIN WITH...

Страница 61: ...simply pressing the lever photos 1 and 2 and can be kept on by raising the lever and turning it 180 see photos 3 and 4 1 2 3 4 The right hand side of the eGROSS eGROSS pro x unit includes the followin...

Страница 62: ...ner The funnel is shown in the following figure This funnel contains a fixative drain filter in order to prevent samples from accidentally falling inside the container The drainage container s cap is...

Страница 63: ...transport trolley in order to load the fixative in the containers containing the baskets with the trays of the recently cut samples The container is NOT provided An example is shown in the figure Whe...

Страница 64: ...loading of the fixative is commanded by the pedal for its assembly please refer to chapter 2 3 1 The fixative leaks through the injector indicated by the circle in the figure below In order to use the...

Страница 65: ...NTROL M is used via the MacroPATH software as illustrated in chapter 3 A FREE USB PORT N can be found on the front right hand side of the eGROSS pro x unit This USB port can be used to connect any typ...

Страница 66: ...oPATH Please refer to the MM161 MacroPATH and MacroPATH Basic QX Series Operator Manual to work with MacroPATH software and to change the language of the Operating System if necessary The Operator Man...

Страница 67: ...alogenated compounds chlorine bromide iodide When working on the stainless steel surface or during the cleaning procedures Never use chlorine based solutions at any concentration or temperature e g bl...

Страница 68: ...n the list above Never leave the stainless steel in contact with foreign materials Do not leave any parts that could rust on the Milestone stations In case of contact wash with water and dry immediate...

Страница 69: ...ing water and if necessary also a brush with nylon bristles 5 Final steps Reposition the tray and the basin cover on eGROSS eGROSS pro x Before removing gloves wash them with soap water and disinfecta...

Страница 70: ...lding down Locking key for three seconds Recommended disinfectants Chlorine based max 10 solution Chlorox Novalsan etc Phenol based Lysol I C Beaucoup Magna Clean Tek Trol etc Alcohol based Cavicide I...

Страница 71: ...it at least 5 minutes before connecting eGROSS eGROSS pro x to the power supply Ensure that eGROSS eGROSS pro x is generally kept clean after each use Do not use abrasive or sharp tools which can dama...

Страница 72: ...ing it with a no 8 spanner or socket wrench Fasten the ventilation attachment using a no 8 spanner or socket wrench Afterwards connect the ventilation pipe and secure it using the supplied strap Conne...

Страница 73: ...cartridge LSTBCN 1kg HEPA H14 LSTH14 K5 11 4kg The filter is studied for formaldehyde and low molecular weight aldehydes fumes removal through chemical absorption HEPA H14 efficiency 99 995 Active car...

Страница 74: ...er and the HEPA filter H14 is one year The maximum estimated lifetime of the active carbon filter cartridges is 6 months estimated value considering an average use of the fan at 50 of the maximum velo...

Страница 75: ...eGROSS pro x eGROSS MM137 004 Operator Manual 75 5 3 Filterbox Kit without HEPA CODE 102920 This filter is the same of the previous one but without the HEPA filter Please refer to the chapter 5 2...

Страница 76: ...nd one or two shelves After deciding where you want to assemble the shelf on the beam prize to extract the green profile from the guides Cut a section of the green profile The length of the cut sectio...

Страница 77: ...shows an example of the final result 5 5 USB Bar code reader 2D includes holder CODE 102011 Barcode reader is useful to automatically enter the patient specimen number to open a new file or retrieve...

Страница 78: ...After deciding where you want to assemble the lamp on the beam prize to extract the green profile from the guides Cut a section of the green profile The length of the cut section must cover the space...

Страница 79: ...e Unit In this case the green profile will be cut in length according to the space that Glove Dispenser will take 5 8 Waste Grinder Mod 66 CODE 102749 Power supply 220 240V 50 60Hz One stage grinding...

Страница 80: ...le sockets All the cablings should be done in conformity with current regulations Do not keep flammable objects as flammable liquids and spray cans near the Waste Grinder The induction motor generates...

Страница 81: ...pro x eGROSS MM137 004 Operator Manual 81 Drainpipe with seal Drain Dedicated allen wrench Be careful the allen is in inches Pneumatic ON OFF button Disposal tubes Pipe support Follow the instructions...

Страница 82: ...ROSS MM137 004 Operator Manual 82 Remove the disposal tubes from eGROSS eGROSS pro x These are the parts removed Remove the drain Loose the screw as shown in the picture Take the disposer drain and re...

Страница 83: ...83 Now check the presence of the parts available Insert the disposer drain including the seal into the sink Position the seal in the other side of the drain Insert the two metal plates as shown in the...

Страница 84: ...the assembly just mounted remains bound to the sink Tight the three screws until the upper metal plate is seated with the seal The result is shown in the picture Connect the disposal tube with seal t...

Страница 85: ...it and tight the metal ring using the Allen wrench provided Connect the flexible tube to the drain of the downdraft Connect the plastic tube to the one attached to the disposer Fix the pipe support on...

Страница 86: ...t to the sewer system and in anyhow follow the current legislation The laboratory drain must be adequate for the use of a grinder Fix the pneumatic ON OFF button in the position showed in the picture...

Страница 87: ...lease read the following notes carefully before using the grinder 5 8 3 Warnings What you should never dispose into the grinder Bones Glass Metal Plastic Wood Oil and fat Paper Gauzes Metal clips Sutu...

Страница 88: ...Grinder stops never put your hands or tools to unlock it but use the allen wrench provided Follow the instructions below What to do in case of blockage or auto shut off of the Waste Grinder Disconnec...

Страница 89: ...Remove the foreign body that causes the blockage Reconnect the power supply What to do in case of slow water flow Disconnect the power supply Call the technical assistance Caution The grinding capacit...

Страница 90: ...polariser filter to reduce reflection 1 5 10 Vesa mount for extra monitor CODE 102945 CODE DESCRIPTION Q TY IMAGE 102945 This optional part is used to attach an extra monitor to the holder beam of eGR...

Страница 91: ...ith IP68 protection against water and dust Available in the following languages code 372352BE Belgian 372352DE German 372352ES Spanish 372352FR French 372352IT Italian 372352RU Russian 372352UK Englis...

Страница 92: ...eless laser in silicone CODE 372363 CODE DESCRIPTION Q TY IMAGE 372363 Silicone USB wireless laser mouse 1 USB 2 AAA batteries are required not included use the screwdriver supplied to unscrew and clo...

Страница 93: ...ument If the unit needs to be returned to MILESTONE SRL for repairs the device must be cleaned and disinfected prior to shipment Any units that have not been disinfected will not be accepted and you w...

Страница 94: ...5 Dispose all electric and electronic parts of the equipment according to the manufacturer Complying with directive 2012 19 EC of the European Parliament and of the Council of 4 July 2012 on waste el...

Страница 95: ......

Страница 96: ......

Страница 97: ......

Страница 98: ......

Страница 99: ......

Страница 100: ...marketing milestonemedsrl com www milestonemed com Via Fatebenefratelli 1 5 24010 Sorisole BG Italy Tel 39 035 4128264 Fax 39 035 575498 Milestone Srl...

Отзывы: