17
Instruction Manual
7.2.5 Setting the treatment positions
Pull up and remove the bed upholstery.
The bed’s setting can be adjusted by the buttons on the main compu-
ter (H) in the foot end.
Treatment position 1
- Move backrest and bed manually into the desired position
- Press SETUP, OP is displayed
- Confirm with ENTER, O.P. is displayed
- Press ENTER for at least 1.5 seconds, message i.O. is displayed.
Position has been saved. Leave the programming modus with SETUP.
The position will be automatically reached when tapping the function
pedal (1) once.
Treatment position 2
- Move backrest and bed manually into the desired position
- Press SETUP, OP is displayed
- Select UP with arrow key
- Confirm with ENTER, U.P. is displayed
- Press ENTER for at least 1.5 seconds, message i.O. is displayed.
Position has been saved. Leave programming modus with SETUP.
The position will be automatically reached when tapping the function
pedal (1) twice.
Caution!
The functions „CF“, „CI“, „Cd“, „FS“, „FC“ and „CL“ are service func-
tions. They may only be changed by trained staff.
H
7.2.6 Changing the default setting of instruments
Enlarged programming instructions see page 21
Enlarged programming instructions see page 21
The default and factory setting of instrument data is programmed to
the maximum. The default setting can be individually adjusted and
saved by the user.
Activate all instruments controlled by the 5-function pedal one after
another and set them at the desired parameters. Then transfer the in-
strument data as follows:
- Press SETUP, OP is displayed
- Select IN with arrow key
- Confirm with ENTER, I.N. is displayed
- Press ENTER for at least 1.5 seconds, message i.O. is displayed
The individual data has been saved for all instruments. Leave pro-
gramming modus with SETUP
Hint:
If you only want to change the setting of one instrument, we recom-
mend that you first switch the unit on and off at the main switch. De-
fault settings of the instrument will be activated by this. Activate the
instrument to be changed, adjust it and save the data (as explained
above).
Caution!
The functions „CF“, „CI“, „Cd“, „FS“, „FC“ and „CL“ are service func-
tions. They may only be changed by trained staff.
The function “instrument data programming (IN)” is integrated by de-
fault from OT1.00251 (upgrade available from OT1.00100 with version
MC-CPU-1.9 or higher).
TA
1
TA
2
TA
3
TA
4
SETUP
ENTER
S
et
up
S
et
up
ENTER
>1,5
Sek
O P
U P
O. P.
U. P.
i.O.
i. O.
ENTER
>1,5
Sek
ENTER
ENTER
Cu
DN
C
u
U
P
C
u
U
P
Cu
D
N
S
et
up
I S
I N
SP
OP-position
is saved
UP-position
is saved
!One step back always with SETUP!
TA
1
TA
2
TA
3
TA
4
SETUP
ENTER
S
et
up
S
et
up
O P
Cu
DN
C
u
U
P
C
u
U
P
Cu
D
N
S
et
up
I S
ENTER
I. N.
ENTER
>1,5
Sek
i.O.
I N
SP
U P
!One step back always with SETUP!
IN-position