MM560 Installation Instructions
26
Setting Pull-to-Open (Closed) Gate Limit
(for push-to-open go to pg. 27)
15
ON
1
3
2
1
2
Control Box Settings
15
1 2 3 4
ON
LEARN
MAST LIMIT
LEARN
SLV LIMIT
S3
S4
S2
OFF
SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN
MAX
3
4
2
1
With gate in OPEN position, turn control box power ON.
Press button on opener remote; gate should start closing. Press button
on opener remote again when gate is in desired CLOSED position.
Press and hold the “ LEARN MAST LIMIT” button for 5 seconds,
or until the alarm sounds.
Press button on opener remote to fully open gate. Closed limit is
set upon reaching fully open position. Test and, if needed, reset
and start over.
2
5
1
Press and hold the “LEARN MAST LIMIT” button for
10 seconds, or until the alarm sounds to clear. Go back to the
setting closed limit steps on the top of this page.
Press button on opener remote to open gate.
15
1 2 3 4
ON
LEARN RMT
LEARN
MAST LIMIT
LEARN
SLV LIMIT
S3
S4
S2
OFF
SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN
MAX
6
Resetting Closed Gate Limit
NOTE: if the gate stops and reverses see “setting obstruction stall
force” page 28.
NOTE: If the unit does not
respond to the transmitter see
“setting personal transmitter
code” page 29