![Microwave networks CM7 Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/microwave-networks/cm7/cm7_user-manual_1789789043.webp)
Microwave Networks
CM7/8 100Base-T System User’s Manual
8/12/03
Page 1-11
Table 1-D. General Specifications
Specification
Value
Digital Interface
10/100BaseT
Up to 100 Mbps, IEEE 802.3
100Base T Channels
Channels
2 x 10/100BaseT auto-negotiating
Connector
2 x RJ-45 per channel, bridged
Bandwidth Priority
Channel 1 priority or No priority
Wayside
1 x DS3/E3 in-band, can be disabled
1 x DS1/E1 out-of-band (optional)
Network Management
SNMP
10BaseT, RJ-45 jack
P4-TeleScan
19.2 kbps RS-485, RJ-11 jack
Local Access
19.2 kbps RS-232, DB-9 jack
Service Channels
Digital
Number of Digital Channels
2
Maximum Data Rate
19.2 kbps (asynchronous)
Audio
Number of Channels
2
Frequency Range
300 to 3400 Hz
Input (Tx) Level
-3.5 dBm (-16 dBm option)
Output (Rx) Level
-3.5 dBm (+7 dBm option)
Idle Channel Noise (narrow band)
23 dBrnC
Orderwire (Optional)
Frequency
300-3400 Hz
Signaling
DTMF (allows all-call, group and local)
Features
Talk Switch, 4-way/4-wire bridge
Wayside Traffic Unit (Optional)
Wayside Traffic Channel
1
Data Rate
19.2 kbps, asynchronous
Connector
RJ-11 Jack
Electrical (Hot-Standby)
Input Voltage Range
±
20 to
±
60 Vdc
Power Consumption (typical)
Std. Pwr. APC Low/High (Non-protected)
115/125 W
Std. Pwr. APC Low/High (Hot Standby)
195/205 W
High Pwr. APC Low/High (Non-protected)
160/220 W
High Pwr. APC Low/High (Hot Standby)
275/335 W
D-High Pwr. APC Low/High (Non-protected)
175/235 W
D-High Pwr. APC Low/High (Hot Standby)
290/350 W
Status/Control/Alarms
External Alarm Inputs
Number of Inputs (with NMU)
4 (8)
Type
Std. - TTL
External Control Outputs
Number of Control Outputs (with NMU)
4 (8)
Type
Form-C Dry Contact (NO, NC, COMM)
Содержание CM7
Страница 2: ......
Страница 4: ...Page iv 5 04 05 CM7 8 100Base T System User s Manual ...
Страница 16: ...Glossary Page xvi CM System Users Manual X Y Z ...
Страница 24: ...Microwave Networks CM7 8 100Base T System User s Manual Pagexxiv ...
Страница 62: ...Chapter 2 Operation Page 2 18 5 02 05 CM 100Base T System User s Manual ...
Страница 64: ...Chapter 3 Module Descriptions Page 3 2 CM7 8 100Base T ...
Страница 88: ...Section 3 3 Transmitter Unit Page 3 3 6 CM7 8 System User s Manual ...
Страница 96: ...Section 3 5 RF Power Supply Unit Page 3 5 4 CM System User s Manual ...
Страница 100: ...Section 3 6 SP Power Supply Unit Page 3 6 4 CM System User s Manual ...
Страница 106: ...Section 3 7 Alarm and Control Unit Page 3 7 6 11 18 03 CM 100Base T System User s Manual ...
Страница 124: ...Section 3 11 SYNDES Page 3 11 6 CM System User s Manual ...
Страница 130: ...Section 3 12 SCU Page 3 12 6 11 18 03 CM 100Base T System User s Manual ...
Страница 138: ...Section 3 13 OWU Page 3 13 8 CM System User s Manual ...
Страница 150: ...Section 3 15 NMU Page 3 15 6 CM System User s Manual ...
Страница 192: ...Chapter 5 Verification Page 5 20 CM System User s Manual ...
Страница 194: ...Chapter 6 Maintenance Page 6 2 7 23 03 CM 100Base T System User s Manual ...
Страница 224: ...Chapter 6 Maintenance Page 6 32 7 23 03 CM 100Base T System User s Manual ...
Страница 225: ...CM System User s Manual Page 1 Place any site research or reference material here Site Engineering ...
Страница 226: ...Site Engineering Page 2 CM System User s Manual ...
Страница 230: ...Appendix A T I Curves Page A 4 CM7 8 100Base T System User s Manual ...
Страница 267: ...Microwave Networks CM System User s Manual PageB 37 ...
Страница 268: ...Appendix B QuikLink Page B 38 CM System User s Manual ...
Страница 282: ...Appendix D Alarm Codes Page D 6 5 02 05 CM 100Base T System User s Manual ...
Страница 290: ...Appendix E Setting Frequency Page E 8 CM7 8 System User s Manual ...
Страница 312: ...CM7 8 100Base T System User s Manual Page I 4 Microwave Networks ...