Page 54
scanCONTROL Output Unit
scanCONTROL 29xx
- Interfaces: 2x Ethernet to connect
scanCONTROL 2910/2960 sensors.
- Indicators (Status LED’s, for detailed description refer to the manual
of the OU-Fieldbus Coupler/Ethernet)
- The system supply is already mounted to the Fieldbus Coupler.
Fig. 30 OU-Fieldbus Coupler/Ethernet with system supply module
System data
Max. number of bus sharing unit
Limited by Ethernet specification
Max. length of fieldbus segment
100 m
Baud rate
10/100 Mbit/s
Technical Data
Number of bus terminals
64
With bus extension
250
Power supply
DC 24 V (-25 % ... +30 %)
Max. input current
280 mA at 24 V
Internal current consumption
450 mA at 5 V
Total current for I/O modules
700 mA at 5 V
Voltage drop at I
max.
< 1 V at 64 I/O modules
Fig. 31 Technical data Fieldbus Coupler/Ethernet
Содержание 4350127.256
Страница 1: ...thicknessCONTROL MTS 8202 LLT C frame Non contact thickness measurement Operating Instructions...
Страница 10: ...Page 10 Overview Technical Data Safety Instructions thicknessCONTROL MTS 8202 LLT 4350127 256...
Страница 26: ...Page 26 Installation and Commissioning Instructions thicknessCONTROL MTS 8202 LLT 4350127 256...
Страница 56: ...Page 56 Declaration of Incorporation thicknessCONTROL MTS 8202 LLT 4350127 256...
Страница 78: ...Operating Instructions scanCONTROL 29xx...
Страница 82: ...scanCONTROL 29xx Appendix A 1 Accessories 62 A 1 1 Recommended Accessories 62 A 1 2 Optional Accessories 63...
Страница 83: ......
Страница 119: ...Page 42 Operation of the Sensor with a PC scanCONTROL 29xx Fig 23 Predefined measuring fields...