Page 38
Mounting and Installation
scanCONTROL 29xx
5.3
Installation Instructions
- Only use shielded cables from the accessories for all connection cables
- Connect the cable shields to the potential equalization on the evaluation unit (switch cabinet, PC housing,
connector housing) and avoid ground loops.
- Lay all connection cables in accordance with the generally applicable measuring technology regulations,
i.e. for example not directly next to pulse-carrying lines, preferably in a separate cable duct.
- The minimum bending radii of the recommended cables for flexible laying must not be less 80 mm.
- MICRO-EPSILON recommends the use of the optionally available power supply PS2020, Din rail mounting,
input 230 VAC, output 24 VDC/2.5 A.
5.4
Getting Ready for Operation, Commissioning
Mount the sensor according to the installation instructions
Connect the sensor to the Ethernet cable.
Connect the sensor to downstream display or monitoring units and to the power supply.
Switch on the power supply.
The sensor must only
be connected to the
peripheral equipment
when disconnected
from the power supply,
i.e only when the
operating voltage is
switched off.
Содержание 4350127.256
Страница 1: ...thicknessCONTROL MTS 8202 LLT C frame Non contact thickness measurement Operating Instructions...
Страница 10: ...Page 10 Overview Technical Data Safety Instructions thicknessCONTROL MTS 8202 LLT 4350127 256...
Страница 26: ...Page 26 Installation and Commissioning Instructions thicknessCONTROL MTS 8202 LLT 4350127 256...
Страница 56: ...Page 56 Declaration of Incorporation thicknessCONTROL MTS 8202 LLT 4350127 256...
Страница 78: ...Operating Instructions scanCONTROL 29xx...
Страница 82: ...scanCONTROL 29xx Appendix A 1 Accessories 62 A 1 1 Recommended Accessories 62 A 1 2 Optional Accessories 63...
Страница 83: ......
Страница 119: ...Page 42 Operation of the Sensor with a PC scanCONTROL 29xx Fig 23 Predefined measuring fields...