![Micom P631 Скачать руководство пользователя страница 196](http://html1.mh-extra.com/html/micom/p631/p631_technical-manual_1784787196.webp)
MAIN:
Phase sequence
[ 010 049 ]
64Z5076C
Parameter
set 1
set 2
set 3
set 4
IDMT1:
Hold time neg PSx
081 115
082 115
083 115
084 115
IDMT1:
Min. trip t. neg PSx
081 117
082 117
083 117
084 117
IDMT1:
Factor kt,neg PSx
081 114
082 114
083 114
084 114
IDMT1:
Release neg PSx
081 116
082 116
083 116
084 116
IDMT1:
Gen.starting modePSx
081 059
082 059
083 059
084 059
Parameter
set 1
set 2
set 3
set 4
IDMT1:
Iref,neg dynamic PSx
081 112
082 112
083 112
084 112
IDMT1:
Iref,neg PSx
081 111
082 111
083 111
084 111
IDMT1:
Rush restr.enabl PSx
081 060
082 060
083 060
084 060
IDMT1:
Character. neg. PSx
081 113
082 113
083 113
084 113
IDMT1:
Rush restr.enabl PSx
[ * ]
IDMT1:
Iref,neg PSx
[ * ]
IDMT1:
Iref,neg dynamic PSx
[ * ]
IDMT1:
Gen.starting modePSx
[ * ]
IDMT1:
Character. neg. PSx
[ * ]
IDMT1:
Factor kt,neg PSx
[ * ]
IDMT1:
Min. trip t. neg PSx
[ * ]
IDMT1:
Hold time neg PSx
[ * ]
IDMT1:
Release neg PSx
[ * ]
DIFF:
Harm.block 1 trigg.
[ 041 118 ]
DIFF:
Harm.block 2 trigg.
[ 041 119 ]
DIFF:
Harm.block 3 trigg.
[ 041 120 ]
IDMT1:
Enabled
[ 038 125 ]
MAIN:
Dynam. param. active
[ 040 090 ]
MAIN:
Protection active
306 001
I̲A,y
I̲B,y
I̲C,y
IDMT1:
Block.tIref,neg> EXT
[ 038 178 ]
1: With start. IN/Ineg
I̲neg/Iref,neg
IDMT1:
Release neg PSx
Setting
1: Without delay
2: Delayed as per char.
I̲neg
1.05 Iref
0: No
1: Yes
Setting
IDMT1:
Character. neg. PSx
1: IEC Standard Inverse
2: IEC Very Inverse
3: IEC Extr. Inverse
4: IEC Long Time Inv.
5: IEEE Moderately Inv.
6: IEEE Very Inverse
7: IEEE Extremely Inv.
8: ANSI Normally Inv.
9: ANSI Short Time Inv.
10: ANSI Long Time Inv.
11: RI-Type Inverse
12: RXIDG-Type Inverse
IDMT1:
Memory 'neg' clear
[ 038 176 ]
IDMT1:
Trip sig. tIref,neg>
[ 038 177 ]
IDMT1:
tIref,neg> elapsed
[ 038 174 ]
IDMT1:
Hold time neg runn.
[ 038 175 ]
IDMT1:
Starting Iref,neg>
[ 038 173 ]
0
1
Fig. 3-104: Negative-sequence current stage
3.23.5
Residual Current Stage
The residual current is monitored by the P631 to detect when it exceeds the set
thresholds. Alternatively, two different thresholds can be active. The “dynamic”
threshold is active for the set hold time for the “dynamic parameters” (see
) and the “normal” threshold is active when no hold time
is running. The IDMT protection will trigger when the 1.05-fold of the set
P631
3 Operation
3-140
P631/EN M/R-11-C // P631-310-650
Содержание P631
Страница 2: ......
Страница 4: ......
Страница 7: ...Changes after going to press...
Страница 8: ......
Страница 16: ...P631 Table of Contents 8 P631 EN M R 11 C P631 310 650...
Страница 56: ...P631 2 Technical Data 2 28 P631 EN M R 11 C P631 310 650...
Страница 236: ...P631 3 Operation 3 180 P631 EN M R 11 C P631 310 650...
Страница 246: ...P631 4 Design 4 10 P631 EN M R 11 C P631 310 650...
Страница 266: ...P631 5 Installation and Connection 5 20 P631 EN M R 11 C P631 310 650...
Страница 276: ...6 8 Configurable Function Keys P631 6 Local Control HMI 6 10 P631 EN M R 11 C P631 310 650...
Страница 548: ...P631 10 Commissioning 10 10 P631 EN M R 11 C P631 310 650...
Страница 568: ...P631 12 Maintenance 12 8 P631 EN M R 11 C P631 310 650...
Страница 570: ...P631 13 Storage 13 2 P631 EN M R 11 C P631 310 650...
Страница 572: ...P631 14 Accessories and Spare Parts 14 2 P631 EN M R 11 C P631 310 650...
Страница 576: ...P631 15 Order Information 15 4 P631 EN M R 11 C P631 310 650...
Страница 582: ...P631 A2 Internal Signals A2 4 P631 EN M R 11 C P631 310 650...
Страница 608: ...P631 A4 Telecontrol Interfaces A4 18 P631 EN M R 11 C P631 310 650...
Страница 637: ......