38 / 72
HBC-series V7 LV+MV
Parameter
Table continue
Legend: H
- choice from discrete values
With respect to possibility of settings is necessary programming controllers
HBC-series
range only by PC with operating system Microsoft
(
Windows XP
,
Vista,
Windows
7
or
Windows
8
) and
USBCOM_4(i)
module with s cable
CC_11
. In your PC must be installed and run pro-
gram
„
Controller 2
“. Installation instruction is in manual „
Installing and running of program Controller 2
“.
Keep in mind default (company) settings of parameters represent only average values. These values are usable as “starting values” for starting
of system (model) testing. In most cases will be necessary many parameters change and adapt for the best behavior of the controller
- respectively of your model
– by your images and requests.
Note:
When your requests on parameter range or parameter type, or some other features, don´t realize these standard specification,
contact
MGM
COMPRO
company please.
Most of the above parameters is common to all types of controllers and the types of controls. Some specific parameters are for any type - ex-
cept that it is always highlighted in the description of parameters. The settings are also dependent on the specific hardware of a particular type.
parameter
range
step
Bank #1
Bank #2
Bank #3
Bank #4
Default settings
Default settings
Default settings
Default settings
P16
Acceleration
(time from 0% to 100%)
0,1 sec.
60 sec.
0,1
0,5 sec.
0,5 sec.
0,5 sec.
0,5 sec.
P17
Acceleration from STOP position
(only for constant rpm mode)
0,1 sec.
60 sec.
0,1
0,5 sec.
0,5 sec.
0,5 sec.
0,5 sec.
P82
Cruise Control ramp
0,1 sec.
60 sec.
0,1
0,5 sec.
0,5 sec.
0,5 sec.
0,5 sec.
P18
Deceleration
(time from 100% to 0%)
0 sec.
60 sec.
0,1
0,5 sec
0,5 sec
0,5 sec
0,5 sec
P22
Brake intensity
0%
100%
1%
30%
--
--
--
P23
Brake intensity in Neutral position
(in STOP position)
0%
100%
1%
0%
--
30%
30%
P25
Brake Ramp
(time to reach full braking force)
0 sec.
60 sec.
0,1
0,2s
0,2s
0,2s
0,2s
P26
Brake Ramp in Neutral
(time to reach full braking force)
0 sec.
60 sec.
0,1
0,2s
0,2s
0,2s
0,2s
P21
Freewheel
H
Yes
Yes
Yes
Yes
P38
Control signal lost masking period
0
60 sec.
10 ms
500 ms
500 ms
500 ms
500 ms
P39
Brake intensity when signal is lost
0
100
%
0
0
0
0
P71
BB data-logging period /
real-time Monitoring
10 ms
100 ms
H
100 ms
100 ms
100 ms
100 ms
P85
Parameters saved to BB, sets+
H
basic
basic
basic
basic
P28
Motor temperature sensor
H
Not monitored
Not monitored
Not monitored
Not monitored
P29
Battery temperature sensor
H
Not monitored
Not monitored
Not monitored
Not monitored
P30
Controller temperature limit
25
110
°C
100°C
100°C
100°C
100°C
P31
Motor temperature limit
60
150
°C
90°C
90°C
90°C
90°C
P32
Battery temperature limit
40
70
°C
55°C
55°C
55°C
55°C
P37
Calibration of motor temp. sensor
Y/N
No
No
No
No
P36
Calibration of battery temp. sensor
Y/N
No
No
No
No
P88
Throttle
– allowed max. limit
1000
3300
1mV
3200
3200
3200
3200
P89
Throttle
– allowed min. limit
0
1500
1mV
100
100
100
100
P15
Communication Address
1
256
1
1
1
1
1
P27
Speed of CAN bus
125 kbit
1 Mbit/s 125kb
125 kb
125 kb
125 kb
125 kb
P35
Version of CAN bus
H
2.0
2.0
2.0
2.0
P14
Telemetry
H
off
off
off
off
P91
Baud rate of RS 232 / 485
10 Bd
1 MBd
1
38400
38400
38400
38400
P79
Signal BL-1
H
Braking lights
Indication of
incoming discharge
Indication of
incoming discharge
Indication of
incoming discharge
P70
Braking resistors control
(activation
)
Y/N
No
No
No
No
P80
Motor beeping
(on / off)
Y/N
Yes
Yes
Yes
Yes
P55
PID regulátor - složka P
P56
PID regulátor - složka I
P57
PID regulátor - složka D